8 Server 

Configuration 

 

The Allworx 10x provides an administrative interface to configure and administer the server.  The 
administrative interface is accessed using a web browser.  Assuming the network settings are set to their 
factory defaults, the steps to connect to this interface are: 
 
1.  Plug your PC into one of the server’s LAN ports. 
 
2.  Set up the PC’s network interface to obtain an IP address automatically (using DHCP). 
 
3.  You may need to release and renew the PC’s IP address to get an address from the server. 
 
4.  Verify that the PC has an IP address on the 192.168.2.xxx network. 
 
5.  Open your browser and enter the URL of http://192.168.2.254:8080. 
 
6.  When the Welcome to Allworx page appears, login using the default password of admin. 
 
When the Home page appears, click on the Install Checklist

 

link (on the left hand side) to bring up a new 

window containing steps necessary to set up a new system.  Each brief step description is followed by a link to 
get to the appropriate administrative web page to execute the step.  These steps are ordered to aid in a 
successful configuration.  Most of the web pages to execute each step contain all the descriptions and help 
necessary to carry out the step.  Use the 

Allworx 10x System Administration Guide

 to supplement the 

information on the web pages when necessary. 
 
If the server has been previously configured for another installation, you should restore it to its factory default 
configuration.  This can be done by: 
 
1.  Rebooting the server to Safe Mode. 
 
2.  Format the disk and perform a Software Update. 

Summary of Contents for Allworx 10x

Page 1: ...Allworx 10x Installation Guide...

Page 2: ...PAGE INTENTIALLY LEFT BLANK...

Page 3: ...nstallation Overview 1 2 Unpacking 2 3 Chassis Views 3 4 Mechanical 5 4 1 Tabletop or Shelf Placement 5 4 2 Rack Mount 5 4 3 Wall Mount 5 5 Electrical 7 5 1 Chassis Ground and Voltage Selection 7 5 2...

Page 4: ...ll other names may be trademarks or registered trademarks of their respective owners Revised February 7 2007 Page 1 1 Installation Overview Installation of the Allworx 10x involves the following steps...

Page 5: ...rs Revised February 7 2007 Page 2 2 Unpacking Open the box and carefully unpack it Save all shipping and packaging materials Verify all items against the parts list shown in Table 1 If any items are m...

Page 6: ...Ds Power Indicates system start up activity Drive Indicates drive activity Alert Indicates drive or other system fault condition 3 RJ 45 10BaseT 100BaseTX Auto Sensing Auto MDI MDIX switched Local Are...

Page 7: ...cting screw 15 Air intake and exhaust vents 300 Main Street East Rochester NY 14445 Toll Free 1 866 ALLWORX 585 421 3850 www allworx com 2007 InSciTek Microsystems Inc All rights reserved Allworx is a...

Page 8: ...et Installation 3 Install the mounting brackets on each side of the chassis using four 8 32 flat head screws 4 Perform the electrical installation as shown in the instructions below before placing the...

Page 9: ...he unit to the wall using appropriate hardware Caution The Allworx server must be securely mounted to the wall to avoid equipment damage or personal injury 300 Main Street East Rochester NY 14445 Toll...

Page 10: ...er Up Sequence Connect the unit to the power source with the AC power cable The server will automatically begin to power up As it progresses through the power up sequence the front panel lights will r...

Page 11: ...audio channel associated with the tip of the plug is used 6 2 Overhead Paging Connect the server to the input of your paging system using a 3 5mm stereo plug audio cable Insert the male cable end into...

Page 12: ...t CO lines DID lines or telephone handsets 10 16 FXS DID lines or telephone handsets Table 3 Analog Telephony Ports The server supports DID lines that use the Wink Start signaling protocol Given the f...

Page 13: ...ss from the server 4 Verify that the PC has an IP address on the 192 168 2 xxx network 5 Open your browser and enter the URL of http 192 168 2 254 8080 6 When the Welcome to Allworx page appears login...

Page 14: ...connected to the LAN and WAN Note Do not plug any network cables into the server without first properly configuring the server Failure to heed this warning may result in a disruption of network conne...

Page 15: ...10 100 E net 10 100 E net Network Server Paging Amplifier Line level audio output 10 100 E net 10 100 E net E net Switch or Hub 10 100 E net Maximum of 16 analog connections LAN WAN RJ 11 In Out Allwo...

Page 16: ...istered trademark of InSciTek Microsystems All other names may be trademarks or registered trademarks of their respective owners Revised February 7 2007 Page 13 11 Physical and Environmental Specifica...

Page 17: ...otify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be...

Page 18: ...or this terminal equipment is 0 1 The REN assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface The termination on...

Page 19: ...ise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le present appareil numerique n emet pas de bruits radioelectriques depa...

Reviews: