![Allwin CS2676FX User Manual Download Page 23](http://html1.mh-extra.com/html/allwin/cs2676fx/cs2676fx_user-manual_2904422023.webp)
CS2676FX Insulation Resistance Tester User Manual
Ver:1.1
Page 23 of 25
7.1
CONNECTION
7.1.1 CS2676FX connection method
Figure 8.1
Note:G is the shield end, preventing the signal interference. Because the top test
resistance is not very high, so the ground shield end can not be connected.
7.2 CS2676FX Test
7.2.1
Connect DUT to tester
You must press the "STOP" key to confirm there is no voltage output, and high-voltage light is off
before connect DUT and tester. After confirmation, connect DUT and tester follow the Figure 8.1. If DUT
is with polarity, please note that the high voltage output is the negative voltage.
7.2.2
Press
“
START
”
to begin
When “START” button is pressed, the tester begin to test, meanwhile high-voltage is output and
the test light is flashing; LED display the resistance value.
Note:
press the "start
” button, L terminal output high voltage until the “stop” button is pressed,
the high voltage will be cut off. So when the tester is in the testing conditions, the test lead, the
DUT and the test probe and the output terminal is with the high voltage, do not touch any part of
the test loop.