Allwin CS2676FX User Manual Download Page 1

 

CS2676FX Insulation Resistance Tester User Manual 

                                                                  Ver:1.1                     

Page 1 of 25 

 

User Manual 

CS2676FX Insulation Resistance Tester

 

 

 

 

The maximum output voltage of the tester can be up to 1kV.

 

                                   

 

* Any incorrect operation maybe cause death.

 

                                                                        * Before operation, please read notice before 

use carefully of chapter2. 

                                                                        * This manual should be beside the operator.

 

Summary of Contents for CS2676FX

Page 1: ...f 25 User Manual CS2676FX Insulation Resistance Tester The maximum output voltage of the tester can be up to 1kV Any incorrect operation maybe cause death Before operation please read notice before us...

Page 2: ...ase send user manual together with the equipment so as not to lose If you find that missing page manual or instructions to be contaminated please contact with the dealer of Allwin company immediately...

Page 3: ...connected to ground If there is no reliable grounding once short circuit exist between the power supply and case or between and high voltage test line and case during the testing process the case wil...

Page 4: ...ge 8 1 7 Check and replace fuses 8 1 8 Grounding WARNING 9 2 Notice before use 10 2 1 Prohibit operation 10 2 2 Emergency treatment 11 2 3 Precautions during testing 11 3 Panel illustration 13 3 1 ill...

Page 5: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 5 of 25 1 Unpacking and installation tester...

Page 6: ...r accessories within the box to see if the test clips are completed Accessories 1 3 Carton and packing materials Please Save the original packing materials for use in future transportation 1 4 safety...

Page 7: ...ent on a sloping surface or shaking of the place is easy to drop and break down 1 4 7 Do not use the tester beside the sensitive receiving equipment or testing equipment If the tester is near these eq...

Page 8: ...th the rear panel voltage selector switch WARNING To prevent malfunction or damage to tester please use the tester in the specified voltage range 1 7 Check and replace fuses Warning To avoid electric...

Page 9: ...ith specifications listed in the 1 7 1 4 The fixed fuse holder should be back in its original location 1 8 Grounding WARNING Improper grounding or not grounding may cause electric shock To ensure safe...

Page 10: ...e don t turn off the power switch except in urgent cases can perform this operation 2 1 2 High voltage output and ground could not be short circuit The high voltage test leads of the tester are strict...

Page 11: ...ose or fall off Connect the test leads with the device under test DUT be sure to connect DUT to current measurement terminal then connect DUT to high voltage terminal If test leads in current measurem...

Page 12: ...rn off the power switch 2 3 7 After the test user must confirm the following At any time before touch high voltage leads high voltage output or the DUT make sure that 1 Power switch is off the display...

Page 13: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 13 of 25 3 Panel Illustration 3 1 Front panel illustration 3 2 Rear panel illustration...

Page 14: ...indicator lights if you are not sure about the resistance range please select the maximum range 2000M and then select the appropriate range according to the display resistance If the resistance is gr...

Page 15: ...the lower limit within the measuring range 12 Current sample 13 Grounded shield end 14 High voltage output During test the output voltage is negative voltage the maximum voltage is 1kVDC 3 2 illustrat...

Page 16: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 16 of 25 4 Function Outline 4 1 Outline 4 2 Function introduction...

Page 17: ...load or the input power supply voltage 4 2 2 Discharge function After the test is finished the voltage will be needed some time to discharge fully after the power is turned off The tester is with the...

Page 18: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 18 of 25 5 Technical parameters...

Page 19: ...Ver 1 1 Page 19 of 25 5 1 Technical Parameters CS2676FX Model CS2676FX Output voltage DC Range 500V 1000V Accuracy 5 3 FS Range Test range 2M 200k 2M 5 2words 20M 2M 20M 5 2words 200M 20M 200M 5 2wor...

Page 20: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 20 of 25 6 Parameters setting 6 1 Power on 6 2 CS2676FX Parameters setting...

Page 21: ...the screen displays the lower limit of the range Users can press or long time press the up and down keys to set the desired lower limit Wherein the lower limit value should not be equal to the upper l...

Page 22: ...CS2676FX Insulation Resistance Tester User Manual Ver 1 1 Page 22 of 25 7 Test Function 7 1 Connect the DUT to the tester 7 2 CS2676FX test...

Page 23: ...T and tester After confirmation connect DUT and tester follow the Figure 8 1 If DUT is with polarity please note that the high voltage output is the negative voltage 7 2 2 Press START to begin When ST...

Page 24: ...is warranted to be free from use for a period of 12 months from the date of shipment to the original end users in different sales spots 2 Accessories is warranted to be free for just months 8 2 2 Main...

Page 25: ...ax 86 25 52101482 Skype trudamao MSN cy mao hotmail com Email trudamao allwin instruments net cn njmaocuiyun 163 com cswangyi 163 com Homepage www csallwin com The copyrights reserved by Allwin Instru...