ALLUSERV CPH2 Service Manual Download Page 6

6

|  

888-892-2213

|  

alluserv.com

troubleshootIng

cautIon: 

Prior to performing any service repair, turn the “On-Off” switch to the “Off” position and unplug the unit from

the electrical power source! 

complaInt 

problem

solutIon

A

unit does not heat but the fan operates

1. Open Hi-Limit thermostat.

2. Loose wiring.

3. Defective heating element.

1.  Reset Hi-Limit or replace if faulty

2. Repair loose wiring

3. Replace defective heating element

b

unit heats but fan does not blow

1. Defective motor.

2. jammed or loose fan blade.

3. Loose wiring

1. Replace motor.

2. Replace or tighten fan blade.

3. Repair loose wiring

C

unit does not operate and light does not

come on

1. no electrical power to unit

2. Faulty power switch.

3. Loose wiring

1. Make sure that unit is plugged in.

Check power at receptacle.

2. Replace “On-Off” switch.

3. Repair loose wiring

D

base temperature too low

1. Lids left open.

2. Cycle time too short.

3. Loose fan blade.

1. Close lids

2. Allow proper cycle time

3. Tighten or replace fan blade.

E

base temperature too high

Faulty operating thermostat

Replace operating thermostat

F

Cabinet not easy to roll/move

1. Debris on wheel of axel

2. no lubrication

1. Remove debris

2. Lubricate/grease casters

g

bases do not dispense properly

1. Faulty springs

2. not enough springs

3. Faulty bushings

4. Debris on guide rods

1. Replace springs

2. Add springs as needed

3. Replace bushings

4. Clean out debris

Summary of Contents for CPH2

Page 1: ...Plate Heater Service Manual Models CPH2 CPH3 888 892 2213 alluserv com...

Page 2: ...allation Start up 4 Spring Adjustment 5 Cleaning 5 Troubleshooting 6 Service Access Information 7 Replacement Parts List 7 Replacement Parts Diagram CPH2 8 Replacement Parts Diagram CPH3 9 Replacement...

Page 3: ...quest for inspection by the carrier within fteen 15 days of the delivery date The carrier will provide you with the proper form It is very important to keep all cartons pack ing materials and skids f...

Page 4: ...the wooden skid If damage is discovered retain all packing materials and immediately le a concealed shipping damage claim with the trans portation company 2 Remove all tape and protective coatings fr...

Page 5: ...unit from electrical power source units have an adjustable thermostat with a range of 175 to 215 F To adjust the thermostat once switches have been turned o and the unit has been unplugged remove the...

Page 6: ...ring C unit does not operate and light does not come on 1 no electrical power to unit 2 Faulty power switch 3 Loose wiring 1 Make sure that unit is plugged in Check power at receptacle 2 Replace On O...

Page 7: ...hat guards the fan blade and heating element This will provide access to the motor blower wheel and heating element replacement parts No Description Part Number CBH2 Qty CBH3 Qty 1 Lid Assembly End 50...

Page 8: ...8 888 892 2213 alluserv com MoDel CPH2...

Page 9: ...alluserv com 888 892 2213 9 MoDel CPH3...

Page 10: ...10 888 892 2213 alluserv com DisPeNsiNg MeCHaNisM silo eleCtriCal sCHeMatiC...

Page 11: ...ims can be made under this warranty agreement for direct special incidental or consequential damages including but not limited to spoilage of products for any reason or system failure Preventative mai...

Page 12: ...alluserV llc 901 West 14th Street Suite 200 Washington MO 63090 888 892 2213 alluserv com Literature 2060 10 2010...

Reviews: