background image

Model / Modéle / Modelo 

#540025

4.7/3.0

4.7/3.0

* Based Upon Peak Electrical Current Consumption • * Puissance Déterminée en Fonction de la Consommation Électrique  • * Calculado en Base a la Corriente Pico Consumida

3.5 PEAK HP

*

/ 3.5HP

*

EN POINTE / 3.5HP

*

DE PICO

10

GALLON

GALONES

OIL LUBRICATED AIR

COMPRESSOR
COMPRESSEUR D'AIR

LUBRIFIÉ PAR HUILE
COMPRESOR DE AIRE 

CON LUBRICACIÓN 

DE ACEITE

INSTRUCTION MANUAL

Do Not Return Your Compressor to the Store!  Call 1-800-423-3598 For Help!

MANUEL D'INSTRUCTIONS

Ne Pas Retourner le Compresseur au Magasin !  Pour Toute Assistance, Appeler le 1-800-423-3598 !

MANUAL DE INSTRUCCIONES

¡No Deveulva su Compresor de Aire a la Tienda!  ¡Llame al 1-800-423-3598 para Solicitar Ayuda!

Summary of Contents for Air-Plus 540025

Page 1: ...GALLON GALONES OIL LUBRICATED AIR COMPRESSOR COMPRESSEUR D AIR LUBRIFI PAR HUILE COMPRESOR DE AIRE CON LUBRICACI N DE ACEITE INSTRUCTION MANUAL Do Not Return Your Compressor to the Store Call 1 800 4...

Page 2: ...truction manual prior to operation of this unit The owner operator shall retain product instructions for future reference The owner and or operator is responsible for maintenance maintaining all decal...

Page 3: ...ngs are secure before putting this air compressor into service If you have any questions or require assistance with damaged or missing parts please contact our factory customer service department at 1...

Page 4: ...compressor running unattended Always turn the power to the off position and do not leave the air compressor until it come to a complete stop When using air accessories consult the owner s manual provi...

Page 5: ...n place Never attempt to repair or make modifications to the tank or its attachments Welding drilling or any other modifications may weaken the tank which may result in damage from rupture or explosio...

Page 6: ...xcess pressure can cause them to explode resulting in serious injury Follow the manufacturers recommended pressure settings for all air tools and air accessories SPECIFICATIONS 3 5 Peak HP 10 Gallon A...

Page 7: ...stead of an extension cord However if the use of an extension cord is unavoidable use only UL listed three wire extension cords that have three pronged ground ing type plugs and three prong receptacle...

Page 8: ...r pressure reaches a predetermined level The safety relieve valve is preset by the manu facturer DO NOT attempt to modify or remove the safety relief valve 9 AIR TANK DRAIN VALVE Moisture is produced...

Page 9: ...Slide foam grip so that it is centered over end of horizontal handle cross piece 2 Position the horizontal handle crosspiece over the tops of the handle receivers lining up the openings in the crossp...

Page 10: ...minute break in period close the tank drain valve The air compressor will build air pressure to the maximum preset pressure cut out pressure and automatically shut off 10 Slowly turn the tank drain v...

Page 11: ...4 Remove the air hose and any air accessories 5 Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture...

Page 12: ...move oil drain plug 6 Allow oil to drain completely Tilt air compressor towards the oil drain to assist draining 7 Clean and replace oil drain plug 8 Refill crankcase with SAE 30 weight non detergent...

Page 13: ...ockwise until the filter is hand tight DO NOT OVERTIGHTEN MOISTURE IN COMPRESSED AIR Moisture is a normal by product of compressing air As the moisture builds during compressor use it can be carried t...

Page 14: ...rd Replace fuse or reset circuit breaker Check for proper fuse amperage Check for low voltage conditions Disconnect any other electrical appliances from cir cuit or operate air compressor on its own b...

Page 15: ...on If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Limit the air pressure to the capacity of the air com pressor Eit...

Page 16: ...oap solution to all fit tings and connections Bubbles will appear at leak age points Tighen or replace leaking fittings or con nections as needed Replace with larger hose or connectors Check the acces...

Page 17: ...17...

Page 18: ...k Shaft Vilebrequin C rter 1 20 53181215 Oil Drain Plug Bouchon de vidange Tap n de drenaje del aceite 1 21 533322 Oil Fill Breather Plug Reniflard du r servoir d huile Tap n respiradero llenado de ac...

Page 19: ...48c 50041038 Exhaust Pipe Fitting Raccord de tuyau d chappement Uni n de la tuber a de escape 2 49 200619620 Tubular Handle w Grip Guidon tubulaire avec prise Mango tubular c agarradera 1 50 40862S23...

Reviews: