Problem Encountered

Possible Cause

Possible Solution

When in the Start/Stop
option, motor runs continu-
ously:

Overheating:

Air continues to leak at
motor/pressure switch
release valve after motor
stops:

Air continues to leak at
motor/pressure switch
release valve while motor
is running:

Air leaks from safety relief
valve:

Air leaks at pump:

Air leaks at fittings:

Air leaks in air tank:

Air blowing from inlet fil-
ter:

Motor/Pressure switch does not shut off
motor when air compressor reaches "cut-out"
pressure and safety relief valve activates.

Air compressor is incorrectly sized.

Poor ventilation.

Dirty cooling fins.

Defective pilot valve, the check valve is stuck
open.

Defective motor/pressure switch.

Check valve stuck in open position.

Possible defective safety relief valve.

Excessive tank pressure.

Blown gaskets.

Fittings are not tight enough.

Defective or rusted air tank.

Damaged inlet (reed) valve.

Move the motor/pressure switch to the "OFF" posi-
tion. If the motor does not shut off, unplug the air
compressor. If the electrical contacts are welded
together, replace the pressure switch.

Limit the air pressure to the capacity of the air com-
pressor. Either use a smaller tool or a larger air com-
pressor.

Relocate the air compressor to an area with an
ample supply of cool, dry, and well-circulated air is
available.

Clean the outer surfaces of the cooling fins on the
pump and motor assembly.

Remove,  clean or replace.

Replace.

Replace check valve. DANGER - Do not disassemble
the check valve with tank pressurized. Open tank pet-
cock valve to allow air to escape from tank prior to
servicing.

Operate safety relief valve manually by pulling on
ring. If it still leaks, it should be replaced.

Defective motor/pressure switch. Replace.

Replace blown gaskets and torque head bolts to 20
ft./lbs. CAUTION - Replace head gasket with a new
one each time the head is removed to ensure proper
sealing.

Tighten fittings where air can be heard escaping.
Check fittings with soapy water solution. DO NOT
OVERTIGHTEN.

Air tank must be replaced. DO NOT ATTEMPT TO
REPAIR AIR TANK!

Contact Factory Customer Service at 
1-800-423-3598.

Summary of Contents for Air-Plus 540010

Page 1: ...1GALLON GALONES OIL LUBRICATED AIR COMPRESSOR COMPRESSEUR D AIR LUBRIFI PAR HUILE COMPRESOR DE AIRE CON LUBRICACI N DE ACEITE INSTRUCTION MANUAL Do Not Return Your Compressor to the Store Call 1 800 4...

Page 2: ...f any substance that might impair their vision dexterity or judgment Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury...

Page 3: ...ngs are secure before putting this air compressor into service If you have any questions or require assistance with damaged or missing parts please contact our factory customer service department at 1...

Page 4: ...compressor running unattended Always turn the power to the off position and do not leave the air compressor until it come to a complete stop When using air accessories consult the owner s manual provi...

Page 5: ...n place Never attempt to repair or make modifications to the tank or its attachments Welding drilling or any other modifications may weaken the tank which may result in damage from rupture or explosio...

Page 6: ...xcess pressure can cause them to explode resulting in serious injury Follow the manufacturers recommended pressure settings for all air tools and air accessories SPECIFICATIONS 3 5 Peak HP 11 Gallon A...

Page 7: ...stead of an extension cord However if the use of an extension cord is unavoidable use only UL listed three wire extension cords that have three pronged ground ing type plugs and three prong receptacle...

Page 8: ...r pressure reaches a predetermined level The safety relieve valve is preset by the manu facturer DO NOT attempt to modify or remove the safety relief valve 9 AIR TANK DRAIN VALVE Moisture is produced...

Page 9: ...Slide foam grip so that it is centered over end of horizontal handle cross piece 2 Position the horizontal handle crosspiece over the tops of the handle receivers lining up the openings in the crossp...

Page 10: ...minute break in period close the tank drain valve The air compressor will build air pressure to the maximum preset pressure cut out pressure and automatically shut off 10 Slowly turn the tank drain v...

Page 11: ...4 Remove the air hose and any air accessories 5 Drain moisture from the air tank by slowly opening the air tank drain valve by turning clockwise Tilt tank to remove all moisture Once all the moisture...

Page 12: ...move oil drain plug 4 Allow oil to drain completely Tilt air compressor towards the oil drain to assist draining 5 Clean and replace oil drain plug 6 Refill crankcase with SAE 30 weight non detergent...

Page 13: ...ockwise until the filter is hand tight DO NOT OVERTIGHTEN MOISTURE IN COMPRESSED AIR Moisture is a normal by product of compressing air As the moisture builds during compressor use it can be carried t...

Page 14: ...rd Replace fuse or reset circuit breaker Check for proper fuse amperage Check for low voltage conditions Disconnect any other electrical appliances from cir cuit or operate air compressor on its own b...

Page 15: ...on If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Limit the air pressure to the capacity of the air com pressor Eit...

Page 16: ...oap solution to all fit tings and connections Bubbles will appear at leak age points Tighen or replace leaking fittings or con nections as needed Replace with larger hose or connectors Check the acces...

Reviews: