Allterco Robotics MyKi Care User Manual Download Page 5

MyKi

 

Care

 

Thermometer

 

(MCT

 

1.0)

  

 

 

USER

 

MANUAL

 

Allterco

 

Robotics

 

LTD.

 

1404

 

Sofia,

 

Bulgaria

            

phone

 

+35929571247

                                                                 

www.MyKi.Care

[email protected]

 

Product

 

specifications:

   

 

 

 

 

 

 

Product

 

name:

  

MyKi

 

Care

 

Thermometer

 

Product

 

model:

   

MCT

 

1.0

 

Weight

 

without

 

battery:

  

Measure

 

specifications
Measure

 

scope

 

34.00

Ԩ

45.00

Ԩ

(93.00

Ԭ

113.00

Ԭ

)

 

Measure

 

accuracy

 

 

+/

‐ 

0.1

 

C

 

(0.18

 

F)

 

Temperature

 

unit

 

C

 

or

 

F

 

Update

 

time

 

Every

 

8

12

 

seconds

 

Light

  

Blining

 

when

 

shaked

 

Software

 

platform

 

iOS

 

7+

 

version

Android

 

5+

 

version

 

Battery

 

Type

 

CR2025,

 

3V/163mAH

 

button

 

battery

 

Work

 

time

 

7

 

days

 

/

 

8h

 

per

 

day

 

Environment

 

specifications

 

Temperature

 

Operating:

 

5

+45

;

 

 

Transportation

 

and

 

storage:

 ‐

20

Ԩ

+55

Ԩ

.

Humidity

 

Operating:

 

25%

95%

non

 

condensing)

 

Transportation

 

and

 

storage:

 

25%

 

 

95%

 

(non

 

condensing)

 

Atmospheric

 

pressure

 

Operating:

 

700hPa

1060hPa;

 

Transportation

 

and

 

storage:

 

500hPa

1060hPa.

 

 

 

Possible

 

problems

 

and

 

solutions:

  

Symptom

  

Solution

 

Device

 

not

 

wake

up

 

when

 

I

 

shake

 

it.

 

Red

 

light

 

do

 

not

 

appear.

  

Check

 

the

 

battery.

 

Carefully

 

open

 

the

 

device

 

and

 

replace

 

the

 

battery

 

with

 

new

 

one.

  

Temperature

 

is

 

not

 

correct

 

after

 

20

 

min

Check

 

the

 

device

 

position.

 

Must

 

be

 

under

 

arm

 

with

 

metal

 

cap

 

connected

 

to

 

the

 

body.

 

Replace

 

the

 

adhestive

 

pad.

 

Thermometer

 

do

 

not

 

connect

 

to

 

the

 

mobile

 

device

 

For

 

children

 

mobile

 

phone

 

should

 

me

 

under

 

10meter

 

from

 

the

 

thermometer.

 

For

 

adults,mobile

 

phone

 

should

 

be

 

under

 

2

 

meters

 

to

 

the

 

thermometer.

  

Check

 

 

are

 

your

 

Bluetooth

 

is

 

activated.

  

Cannot

 

remember

 

mu

 

account

 

details.

  

Create

 

new

 

account

 

and

 

add

 

themormter

 

to

 

it

 

or

 

contact

 

with:

 

[email protected]

 

Guidance

 

and

 

manufacture’s

 

declaration

 

of

 

EMC

 

The

 

device

 

is

 

intended

 

for

 

use

 

in

 

the

 

electromagnetic

 

environment

 

specified

 

below.

 

The

 

customer

 

of

 

the

 

user

 

of

 

the

 

device

 

should

 

assure

 

that

 

it

 

is

 

used

 

in

 

such

 

an

 

environment.

 

Emission

 

test

 

Compliance

 

RF

 

emissions

 

CISPR

 

11

 

Group

 

1

 

RF

 

emission

 

CISPR

 

11

 

Class

 

B

 

Harmonic

 

emissions

 

IEC

 

61000

3

2

 

Not

 

applicable

 

(Battery

 

operated

 

device)

 

Voltage

 

fluctuations/

 

flicker

 

emissions

 

IEC

 

61000

3

3

 

Not

 

applicable

 

(Battery

 

operated

 

device)

 

SAR

 

…………….

 

Summary of Contents for MyKi Care

Page 1: ...possible source of interference as they may emit higher levels of electromagnetic radiation The thermometer is not sterile Doctor should diagnose clinical symptoms only with using the thermometer as subsidiary This product has been calibrated No other routine maintenance and calibration is needed in addition to the replacement battery If the system upgrade please update the program It is very unli...

Page 2: ...rity to operate the equipment FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in acc...

Page 3: ...t patient data 3 Shake the Thermometer for 3 seconds during the red light start blinking for 5 seconds 4 Press on the ID of the Thermometer 5 Place the Thermometer under the arm with metal part to the body 6 Put the adhesive pad carefully If you need to re place change the adhesive pad Change adhesive pad every 2 hours during the day and 6 8 hours during the night ...

Page 4: ... watch the thermometer data from unlimited devices at same time For that all devices should share same account Only one of all devices should be up to 10 meters to the thermometer All data automatically upload to the cloud and all other devices can see whenever they are You should to have internet connection to all devices Set correct alarm setting base of your requirements The alarm maybe not wor...

Page 5: ...n I shake it Red light do not appear Check the battery Carefully open the device and replace the battery with new one Temperature is not correct after 20 min Check the device position Must be under arm with metal cap connected to the body Replace the adhestive pad Thermometer do not connect to the mobile device For children mobile phone should me under 10meter from the thermometer For adults mobil...

Page 6: ...E Max RF output power Bluetooth 0 70dBm Hardware Version MT01CY Software Version FW MT01 Environmental Conditions Working Temperature 5 45 Working humidity 25 95 RH Bluetooth can be used in Europe without restriction Hereby Allterco Robotics declares that this MyKi Care Thermometer MCT 1 0 is In compliance with the essential Requirements and other relevant provisions of RE Directive 2014 53 EU ...

Reviews: