Output function selection:  

 

During memorisation of the devices, activation of the alarm can be programmed in the case 
of an alarm to do this, proceed as follows:  

01. Select the required output by pressing S2 repeatedly (SEL.CAN); the relative led of the 
ALL output illuminates;  
02.Press the key S3 repeatedly (PROG.OUT) to select the required function (see number of 

flashes in Table 2);  
03. Memorise one or more devices for each output, performing the action specified in the 

table below. The efficiency of an output (opening and closing) can be checked by simply 
passing from one function to another as described in point 02 

 

 

 

 
 

 
 

 

 

 