ALLNIC AUDIO L-6500 Owner'S Manual Download Page 7

 

 

DO consider using a high quality power cord and inter-connects, both inputs and 
outputs. The L-6500 is a highly sensitive piece of electronic equipment designed for 

neutrality and will output what you put into it. Allnic’s Zero Loss Technology cables will 

work synergistically with the L-6500. 

 

DO try to place the L-6500 away from major sources of RFI and EMI; though well 

shielded, the L-6500 will function best away from large power transformers and other 

sources of such interference. 

 

B. 

POWER CONNECTION 

 

The L-6500 uses a standard three prong male 15 Amp IEC connection for AC input. You need to 

use a power cord with a female three prong 15 Amp IEC connector at one end. The IEC 

connection is on the left-hand side of the chassis (facing the front), toward the chassis rear (See 

Figure 1). 

 

The L-6500 you have purchased is set internally for AC 110/120 volt – 60 HZ, or 220/230 volt – 

50 Hz operation. There is no way to change this to another AC setting without return of the unit 

to the factory for re-wiring, at the owner’s cost, including transport both directions. 

 

C. 

INPUTS 

 

There are five (5) inputs. Line 1, 2 and 3 are balanced connections (XLR type connectors) on the 

rear panel (see Figure 2). The remaining two (2) line inputs are RCA type, single-ended 

connections. None of the inputs is intended especially for connection to any particular device. 

Turn the “Selector” switch located on the right of the front panel adjacent to the right meter to 

select the desired input. A selected input is indicated by illumination of its identically numbered 

input light on the front panel (see Figure 4).  

 

NO PHONO STAGE - The L-6500 is a line-stage preamplifier and does NOT have a built-in phono 

preamplifier section. You will need a phono preamplifier if you want to use a turntable with the 

L-6500. You can connect your phono preamplifier to any of the five inputs, provided you have 

the appropriate types of connections or adaptors. 

 

The L-6500 has been designed and manufactured to work most synergistically with Allnic Audio 

phono preamplifiers, power amplification products, and ZL Technology cables. 

 

D. 

OUTPUTS 

 

The L-6500 has three pairs of outputs. The right channel outputs are on the right side of the 

chassis and the left channel outputs on the left, facing the rear panel (the reverse if facing the 

front panel - see Figure 2). One (1) output pair is balanced (i.e., separate ground), using XLR 

connectors; two (2) pairs are single-ended unbalanced, using RCA type connectors.  

 

Near the rear of the top plate of the L-6500 chassis there is a switch to select either the 

balanced or single-ended connections. The switch is labelled “RCA OUT GROUND”. (See Figure 

5). Please set the output selection switch to the output connection you are want to use: for RCA 

OUT – switch toward rear. For GROUND (XLR out) – switch toward front. If you set the switch to 

balanced/XLR and then connect your cables to an RCA output (output 2 or 3), or vice-versa, 

audible hum will be introduced. 

 

Summary of Contents for L-6500

Page 1: ...ALLNIC AUDIO L 6500 LINE STAGE PREAMPLIFIER OWNER S MANUAL...

Page 2: ...device will be rewarded by its excellent operation for years to come Please read this entire manual before you connect the L 6500 Line Stage Preamplifier to the other components of your system and th...

Page 3: ...ation Location Power Connection Inputs Outputs Remote Control 6 7 7 7 8 INITIAL POWER ON 9 OPERATION 9 CURRENT METERS 9 TUBES 9 SPECIFICATIONS 10 WARRANTY 11 FIGURES 11 Please read about SAFETY before...

Page 4: ...attage is transferred there is still a transformer loss of about 10 of wattage voltage is not affected Transformer coupling is superior to capacitor coupling However all the advantages of transformer...

Page 5: ...e As are all Allnic Audio products the L 6500 is fully RoHS EU Reduction of Hazardous Substances regulation compliant in construction and materials WHAT S IN THE BOX Please check that the shipping box...

Page 6: ...is and glass Use only a soft lint free cloth dampened slightly with water only NO cleaning fluids to clean the faceplate meter glass and chassis B Connectors You may use any good quality contact clean...

Page 7: ...tch located on the right of the front panel adjacent to the right meter to select the desired input A selected input is indicated by illumination of its identically numbered input light on the front p...

Page 8: ...re ready to turn on the power for your L 6500 Before you power up the L 6500 though be sure you have CAREFULLY AND SLOWLY removed ALL the cardboard cushion materials from inside the tube chimneys ensu...

Page 9: ...channel The needle should be between the two parallel lines just left of centre on the meter face Any failure of the tubes or circuits in one or the other of the L 6500 s channels is indicated by the...

Page 10: ...N Ratio 90dB CCIR 1kHz Maximum Output 15V RMS Non clipping Output Impedance 150 Constant Power Consumption 30W at 110 120V 60 Hz Tubes 5842 equivalent to WE417A CV3789 F7004 2 gain stage 7233 x 1 no...

Page 11: ...er s warranty period provided as stated below no unauthorized repairs or modifications have been performed on the product Date of purchase is the date indicated on the invoice for the product issued b...

Page 12: ...12 Figure 2 L 6500 Rear Panel View Figure 3 L 6500 Remote Control...

Page 13: ...13 Figure 4 L 6500 Front Panel View...

Page 14: ...14 Figure 5 L 6500 Top View...

Reviews: