ALLNIC AUDIO A-6000 Owner'S Manual Download Page 7

7

TUBES AND TUBE BIAS

Each A-6000 uses the following tubes:

Four (4) x 300B

One (1) x 6GV8

Because of the individual bias for each 300B, it is not 

necessary to use a matched quad in the A-6000. 

If the needle of a current meter for a 300B has moved to the 

left of the parallel lines on the meter face, using an

appropriately bladed screwdriver, adjust the potentiometer 

directly in front of that tube’s location by turning it clockwise 

until the needle has returned to between the meter’s parallel 

lines. If the meter needle has moved to the right of the 

parallel lines on the meter face, turn the potentiometer 

control counter-clockwise to correct.

If a meter’s needle drops to the left limit of the meter’s face 

during operation, this indicates a failure of the related 300B 

tube. You must turn off the A-6000 and replace both the fuse 

(0.5A, 250V, 20mm glass type) for that tube and the 300B. To 

replace a fuse, using a screwdriver, simply turn the top of the 

fuse cap counter clockwise. It will spring out holding the fuse. 

Replace the fuse, push the fuse cap down and turn it 

clockwise; it will lock itself.  If you have any questions about 

doing this, please contact Hammertone Audio for assistance.

You may use any 300B type tube in the A-6000, including the 

newer higher voltage varieties. Of course, you will have to 

adjust the bias back into the area between the two parallel 

lines of the meter for a tube when it is replaced. Please refer 

to Figure 5 for tube locations.

All consequences of changing or attempting to change tubes 

are borne by the user unless by express agreement between 

the owner and Hammertone Audio. Allnic Audio and 

Hammertone Audio are not liable in any way whatsoever for any 

injury or loss incurred by the user or for damage to the A-6000, 

any of its parts, or tubes or replacement tubes resulting from the 

user changing or attempting to change tubes.

SPECIFICATIONS FOR THE ALLNIC AUDIO A-6000 300B SET 

MONOBLOCK POWER AMPLIFIER

Output Power:                50w (8

Ω load, at 1KHz)

Distortion:                        0.3% at 1KHz, 2.83V

Frequency Response:      20Hz - 20KHz Flat

S/N Ratio:                          -80dB (CCIR, 1KHz)

Damping Factor:               10 at 8

Ω load at 1KHz

Voltage gain:                      +24dB

Input Impedance:              100K

(single-ended, unbalanced)

Input Sensitivity:                0.7V for rated power

Tubes:                                  300B X 4 (power triode)

                    6GV8 X 1 (driver tube - equivalent to

                    ECL85)

Dimensions:                       (W x D x H) 430mm (16.93 inches) x

                                                   470mm (18.51 inches) X 240mm

                                                  (9.45 inches)

Weight:                                40Kg (88.2 lbs) net per monoblock.

                                                   55Kg (121 lbs) shipping weight per

                                                   monoblock. 

WARRANTY

All Allnic Audio amplifier products are warranted against materials and manufacturing defects for parts, excluding tubes, and 

labour for two (2) years from date of purchase. Tubes are warranted against materials and manufacturing defects for one (1) year 

from date of purchase. The warranty is transferable for the balance of the original purchaser’s warranty period, provided, as 

stated below, no unauthorized repairs or modifications have been performed on the product. Date of purchase is the date 

indicated on the invoice for the product issued by Hammertone Audio.

For the warranty to be valid, a defective product must be returned to Hammertone Audio for service prior to any unauthorized 

attempt to repair. Any repair work on an Allnic Audio product not specifically authorized by Hammertone Audio will void the 

warranty on the product.

Reviews: