English - 3 / 12
6-1622780 - rev.4 - 02/08/2021
WIRING DIAGRAM
POWER SUPPLY
Black / -
Ground
} VCC
Red / +
+Vcc
RELAY 1
Rose / COM1
Common Relay 1
} NO1
White / NO1
Contact Normally Open Relay 1
Rose / COM1
Common Relay 1
} NC1
Clear Blue / NC1
Contact Normally Close Relay 1
RELAY 2
Purple / COM2
Common Relay 2
} NO2
Blue / NO2
Contact Normally Open Relay 2
Purple / COM2
Common Relay 2
} NC2
Grey / NC2
Contact Normally Close Relay 2
EXIT BUTTON
Orange / BP1
Button relay 1
} BP1
Green / GND
Ground
Yellow / BP2
Button relay 2
} BP2
Green / GND
Ground
DOOR CONTACT
Brown / BP1
Button relay 1
} CP
Green / GND
Ground
PROGRAMMATION
KEY:
O
= LED Orange;
G
= LED Green;
R
= LED Red;
= LED flashing
= Small sound;
= Long sound
Enter programming mode
Enter the MASTER CODE twice.
(default MASTER CODE = "1234")
O
Exit programming mode
Press
once.
G
Note: Exit programming mode is automatic after 60 seconds idle.
Change code digits number
Attention: This operation delete every registered codes.
Enter programming mode
.
Select the menu by pressing
O
Enter "
X
" the digits number (from 2 to 6).
Defaults Master Codes:
X=2 –> "12"; X=3 –> "123"; X=4 –> "1234"; X=5 –> "12345"; X=6 –> "123456"
O
Exit the programming mode
.
Summary of Contents for AM1 PAD
Page 1: ...AM1 PAD 6 1622780 ITALIANO rev 4 02 08 2021...
Page 10: ...10 12 Italiano 6 1622780 rev 4 02 08 2021 CODICI MEMORIZZATI REL 1 SLOT DI MEMORIA NOME CODICE...
Page 13: ...AM1 PAD 6 1622780 ENGLISH rev 4 02 08 2021...
Page 22: ...10 12 English 6 1622780 rev 4 02 08 2021 STORED CODES RELAYS 1 MEMORY RANK NAME CODE...
Page 25: ...AM1 PAD 6 1622780 FRAN AIS rev 4 02 08 2021...
Page 37: ...AM1 PAD 6 1622780 ESPA OL rev 4 02 08 2021...
Page 49: ...AM1 PAD 6 1622780 DUTCH rev 4 02 08 2021...
Page 58: ...10 12 Dutch 6 1622780 rev 4 02 08 2021 OPGESLAGEN CODES RELAIS 1 GEHEUGENSLEUF NAAM CODE...