6
ENGINE/GENERATOR
ISUZU 3CD1
Diesel Engine
Starting:
12V Electric 8D Battery
Oil sump capacity:
6.7 qts (6.3 L)
Low Oil Pressure Shutdown: Solenoid actuated fuel
rack instant shutdown
Generator: 8kw Newage
DIMENSIONS
Height:
6'
Length:
16'
Width:
6' 8
SPECIFICATIONS AND SERIAL NUMBERING LOCATION
HEATERS
Two (2) I.C.E. Frost Fighter OHV 600
500,000 BTU each,
60
°
solid nozzle
WEIGHT
Empty:
3,500 lbs.
With Fuel:
4,651 lbs.
Each standard heater includes one (1) 16 in.
heated air outlet, which connects easily to the
ducting. Limit to 45 feet of 16" ducting.
Heated Air Output: 3,000 CFM per heater w/o duct.
Temperature Rise:180
°
with duct creating
0.5 in. static pressure
Operating Time: 1,000,000 BTU- More than 24
hours without refueling
SERIAL NUMBER LOCATION
ISUZU 3CD1
Diesel Engine
TRAILER: Plate attached to right rear corner of frame
ISUZU ENGINE: Plate attached to top of valve cover
GENERATOR: Serial tag located on decal on the left
side of Newage generator (side nearest fuel tank)
FUEL SYSTEM
Fuel Requirements: No.1 fuel oil
Fuel Capacity: 191.1 Gallons
Fuel Consumption:
Engine: ISUZU 3CD1 0.5 gal/hour (1.9L/hr)
Heaters, ea.: 500,000 BTU 3.0 gaI/hour
6. Check igniter tips for correct location for the unit you are setting up. Adjust if necessary. (see
owners manual)
For the OHV 600:
·
5/32 apart
·
¼” above center of nozzle
·
1/8” in front of nozzle
7. Re-install the fuel rail, hook up fuel lines etc.
8. Restart the heater and check the flue gas for smoke using the True-Spot Smoke Tester.
9. If you get a smoke test reading in the 2 to 3 range you will be ready to fine tune the burner to
achieve a #1 or possibly a 0 on the smoke scale. If you still have heavy smoke, you may have to
go down another nozzle size to be able to get the burner to burn efficiently.
Fine Tuning the Frost Fighter Burners
1. Use the True-Spot Smoke Tester to determine where you are on the Smoke Scale.
2. To reduce the amount of smoke, open the band 1 or 2 numbers and recheck with the True-Spot
Smoke Tester.
3. Make further adjustments if necessary to achieve the lowest number you can on the Smoke Scale.
4. Tighten the air band and shutter-securing screws to prevent them from moving after you have
made the adjustments.
MAXI-HEAT
®
SETUP PROCEDURE
Not
for
Reproduction
Summary of Contents for Maxi-Heat Series
Page 16: ...14 TAILLIGHT WIRING SCHEMATIC N o t f o r R e p r o d u c t i o n ...
Page 17: ...15 MAXI HEAT ELECTRICAL SCHEMATIC Honeywell Control N o t f o r R e p r o d u c t i o n ...
Page 18: ...16 CONTROL BOX AND GEN SET WIRING N o t f o r R e p r o d u c t i o n ...
Page 19: ...17 ENGINE WIRING SCHEMATIC ISUZU 3CD1 ENGINE N o t f o r R e p r o d u c t i o n ...
Page 22: ...N o t f o r R e p r o d u c t i o n ...
Page 24: ...TRAILER ASSEMBLY PARTS AND ACCESSORIES A 1A 1 2 3 4 5 6 N o t f o r R e p r o d u c t i o n ...
Page 36: ...OPTIONAL PARTS AND ACCESSORIES D 1A N o t f o r R e p r o d u c t i o n ...
Page 38: ...2 3 1 4 5 D 2A OPTIONAL PARTS AND ACCESSORIES N o t f o r R e p r o d u c t i o n ...