![Allison Transmission 3000 MH Series Operator'S Manual Download Page 20](http://html1.mh-extra.com/html/allison-transmission/3000-mh-series/3000-mh-series_operators-manual_2903290020.webp)
Digital Display.
During normal operation, if
D
(Drive) is selected, the digital
display shows the highest forward range attainable for the shift schedule in use.
Abnormal operation is indicated by the WTEC III digital display as follows:
•
When all segments of the digital display are illuminated for more than
12 seconds, the ECU did not complete initialization.
•
When the digital display is blank, there is no power to the selector.
•
When the display shows a “
\
/
\
” (cateye), a selector-related fault code has
been logged.
•
Conditions which illuminate the
CHECK TRANS
light disable the shift
selector and the digital display displays the range actually attained. For a
detailed explanation, refer to the CHECK TRANS LIGHT paragraph in the
DRIVING TIPS section.
Abnormal operation is indicated by the Allison 4
th
Generation Controls digital
display as follows:
•
When all segments of the digital display are illuminated, the shift selector
did not complete initialization.
•
When both digital displays remain blank for 10 seconds after initialization
and then show a “
\
/
\
” (cateye), the shift selector is unable to communicate
with the TCM or has experienced an internal fault.
•
When the display shows a “
\
/
\
” (cateye), a selector-related fault code has
been logged.
•
Conditions which illuminate the
CHECK TRANS
light disable the shift
selector. The SELECT digit is blank and the MONITOR digit displays the
range actually attained. For a detailed explanation, refer to the CHECK
TRANS LIGHT paragraph in the DRIVING TIPS section.
The transmission will not shift into range if a
CHECK TRANS
code is active.
When the display shows
R
or
D
has been requested and the display is
fl
ashing,
the requested range has not been achieved due to an inhibit function.
Some inhibit functions are vehicle-related and do not result in diagnostic codes.
Some examples are mentioned in the Range Selection tables at the end of this
Section.
Check for active codes if no other inhibit function has been located. Once
D
(Drive) is attained, the transmission will shift into the lowest range programmed
for the
D
(Drive) position, usually
fi
rst-range.
Display Mode/Diagnostic Button.
The
DISPLAY MODE/DIAGNOSTIC
button
allows access to optional
fl
uid level check information and diagnostic code
information. Press the
DISPLAY MODE/DIAGNOSTIC
button once to obtain
transmission
fl
uid level information and a second time to obtain diagnostic code
information.
19