Nozzles / Reflector - change
Danger – can cause burns!
Do not touch the heating element tube and nozzle while they are hot.
Allow the tool to cool down before replacing the nozzle or reflector.
Installation
• The installation must ensure that
– only cold air is supplied.
– no excess (heat) residue builds up.
– the device is not subject to jets of hot air from another device.
• Protect the VULCYAN SYSTEM from mechanical vibrations and shocks.
• Fasten the tool on the
mounting base (15)
using four screws Ø M6.
• For installation dimensions, see page 3 (Size).
Air supply
• The integrated blower serves as an air supply (note direction of rotation and compression heating).
• In order to protect the device and heating element, the specified minimum air volume must never be fallen below
and the maximum temperature (hottest point measured 3 mm in front of the heating element tube) must never
be exceeded (see technical specifications). If the minimum air volume is fallen below, the heat output must
be interrupted immediately.
• Reduce air flow as required by use of the
air slide (9)
.
• Observe direction of air flow.
• Use Leister stainless steel filters if the air is dusty. Slides onto
flange (8)
. In the case of particularly critical dusts
(e.g. metal, electrically conductive or damp dusts), special filters must be used to avoid short-circuits in the tool.
Attention: always operate device with air supply !
Connection
• The VULCAN SYSTEM must be connected by qualified personnel.
• A suitable device for full disconnection from the mains must be provided in the mains connection!
• It must be ensured that the connection lines do not come into contact with the heating element tube and are not
exposed to the hot air jet.
• The device must be connected in accordance with the connection diagram and the termi-
nal arrangement on page 4 (Wiring Diagram) and page 5 (Interface) of the operating instructions:
– Carry out wiring in the
connection housing (12)
.
•
ATTENTION:
check dip switch settings (see chapter Configuration internal dip switch).
• Mount
connection housing cover (12)
with the
screws (13).
• Connect VULCAN SYSTEM to the electrical mains.
• Slide corresponding nozzle or reflector onto
heating element tube (14)
, if required.
• It must be ensured that the hot air can flow out freely, as otherwise the device can
be damaged by the excess heat building up (risk of fire !).
• Attention: comply with minimum air volume as per technical data.
• Switch on mains.
• Allow device to cool down after heating mode.
14
Summary of Contents for LEISTER VULCAN SYSTEM
Page 1: ...VULCAN SYSTEM ...