508107-01
Issue 2041
Page 2 of 58
Technical Specifications - A93UH1E
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nominal
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Upflow/Horizontal
A93UH1E030B12A
30000
29000
93.0%
1.5 - 3
1/2
120 - 60 - 1
15
6.8
40
129
A93UH1E045B12A
44000
42000
93.0%
1.5 - 3
1/2
120 - 60 - 1
15
6.8
40
129
A93UH1E070B12A
66000
63000
93.0%
1.5 - 3
1/2
120 - 60 - 1
15
6.8
40
133
A93UH1E090C12A
88000
84000
93.0%
1.5 - 3
1/2
120 - 60 - 1
15
6.8
40
147
A93UH1E090C16A
88000
84000
93.0%
2.5 - 4
1/2
120 - 60 - 1
15
8.4
40
151
A93UH1E110C16A
110000
104000
93.0%
2.5 - 4
1/2
120 - 60 - 1
15
8.4
40
163
A93UH1E110C20A
110000
105000
93.0%
3 - 5
1/2
120 - 60 - 1
15
10.9
40
169
Note: For vent length and clearances to combustibles, please reference installation instructions.
MODEL NUMBER GUIDE
Numeric Code
A = Aluminized Heat Exchanger
12 = 3 Ton add on cooling
16 = 4 Ton add on cooling
20 = 5 Ton add on cooling
B = 17.5 Width
C = 21.0 Width
A = Flagship
93 = 93% Efficiency
UH = Upflow/Horizontal
DF = Downflow
1 = 1 Stage
E = High Efficiency Motor
Heating Input x 1000
A 93 UH 1 E 110 C 20 A - 01