508096-01
Issue 2037
Page 5 of 34
Technical Specifications - 80G1UHE
MODEL NUMBER GUIDE
Rev Code
Revision
L = Low Nox
Nom. CFM x 100
08 = 2 Ton add on cooling
12 = 3 Ton add on cooling
16 = 4 Ton add on cooling
20 = 5 Ton add on cooling
Blower Drive
P = PSC
E = High Efficency
V= Variable Speed
AFUE
80 = 80% Efficency
Gas
G = Gas
Stages
1 = one Stage
Configuration
UH = Upflow/Horizontal
BTUH Input
Heating Input x 1000
Cabinet Width
A = 14.5” width
B = 17.5” width
C = 21.0” width
80 G 1 U H 110 C E 20 (L) -01
PHYSICAL AND ELECTRICAL DATA
Model
Input
(Btuh)
Output
(Btuh)
AFUE
(ICS)
Nom.
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max.
Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Upflow / Horizontal
80G1UH045AE12(L) 44,000
36,000
80.00%
1-1/2 — 3
1/2
120-60-1
15
6.8
40
111
80G1UH070AE12(L) 66,000
53,000
80.00%
1-1/2 — 3
1/2
120-60-1
15
6.8
40
111
80G1UH070BE12(L) 66,000
53,000
80.00%
1-1/2 — 3
1/2
120-60-1
15
6.8
40
127
80G1UH090BE16(L) 88,000
72,000
80.00%
2-1/2 — 4
1/2
120-60-1
15
8.4
40
142
80G1UH090CE20
88,000
72,000
80.00%
3 — 5
1/2
120-60-1
15
10.9
40
152
80G1UH110CE20(L) 110,000
90,000
80.00%
4 — 5
1/2
120-60-1
15
10.9
40
160
80G1UH135DE20
132,000 107,000
80.00%
4 — 5
1/2
120-60-1
15
10.9
40
178
Note: For vent sizing and clearances to combustibles, please reference installation instructions.