Powering up the camera
Plug the 12-pin Hirose connector into the camera and wait for the boot phase to
complete.
Hirose 12-pin connector: colors and pins for power supply
When connecting an open-ended cable to a Hirose 12-pin connector, ensure
that the pins are connected to the correct wire as described in the table below.
Note that for powering up the camera, the power connection is necessary only.
Pin
Color
Signal
I/O
Level
Description
1
Blue
Camera
GND
In
GND for
RS232 and
ext. power
Ground for
camera
power supply
and RS232
2
Red
Camera
Power
In
7 to
25 VDC
Camera
power supply
2
6
5
4
11
3
10
7
8
9
1
12