background image

GE4000 User Manual 

 

70-0030A-D

 

AVT Inc. 

 

 

9

Item 7: AUXILIARY POWER PORT 

This port is required to provide power to the camera. 

This  port  provides  threaded  captivation  of  the  power  cable  if  required.    The  captivated  cable 
mating  connector  is  the  Switchcraft  760K.    This  connector  can  be  purchased  from  Prosilica  or 
from 

http://www.digikey.com

Cameras  designated  as  “A”,  with  serial  number  02-2xxxA-xxxxx  can  accept  an  input  voltage 
range of 5V to 17V DC. 

Cameras designated as “C”, with serial numbers 02-2xxxC-xxxxx and later versions can accept 
an input voltage range of 5V to 24V DC. 

However the suggested nominal voltage is 12V and cameras are tested at 12V. 

Cameras will normally include a power supply.  However compatible power supplies can also be 
ordered  separately  from  Prosilica  (Prosilica  P/N  02-8000A  for  North  America  or  Prosilica  P/N 
02-8001A  for  a  Universal  supply).  The  inner  conductor  is  positive  power  and  the  external 
conductor is ground. 

 

 

THE CAMERA POWER SUPPLY OPERATES MOST EFFICIENTLY AT 12V. 

 

 

Summary of Contents for Prosilica GE4000

Page 1: ...Allied Vision Technologies Canada Inc 101 3750 North Fraser Way Burnaby BC V5J 5E9 Canada USER MANUAL April 21 2010 GE4000 GE4000C...

Page 2: ...ecifications 2 Supported Features 3 Mechanical 4 Connections 5 Cleaning the Sensor 10 Adjusting the F mount 11 Camera Installation 13 System Optimization 18 Trouble Shooting 20 Addendum 23 GE IO Schem...

Page 3: ...shipping VERIFY ALL EXTERNAL CONNECTIONS Verify all external connections in terms of voltage levels power requirements voltage polarity and signal integrity prior to powering this device CLEANING This...

Page 4: ...Trigger Jitter 10ns Tpd 90ns Operating Temperature 0 to 50 Celsius Operating Humidity 20 to 80 non condensing Size 66mm height x 66mm width x 111mm length Weight 391g 402g for GE4000C Hardware Interf...

Page 5: ...seconds in 1 microsecond increments Gain 0 to 25dB Region of Interest ROI independent x and y control with 1 pixel resolution Horizontal Binning 1 to 8 pixels Vertical Binning 1 to full resolution of...

Page 6: ...70 0030A D AVT Inc 4 Mechanical 110 6 M3 3MM DEEP 16 PLCS TYP 50 TYP 26 TYP 49 9 66 66 All dimensions are in mm Add 0 3mm for color cameras due to addition of IR blocking filter Figure 1 GE SERIES mec...

Page 7: ...GE4000 User Manual 70 0030A D AVT Inc 5 Connections 5 6 1 7 4 3 2 Figure 2 GE SERIES connection diagram...

Page 8: ...neral Purpose I O Pin out Camera rear view 12 Isolated Ground The General Purpose I O port uses a Hirose HR10A 10R 12SB connector on the camera side The mating cable connector is Hirose HR10A 10P 12P...

Page 9: ...Ethernet port to a peripheral device connected to the camera ISOLATED GROUND These signals are internally connected to isolated ground At least one of these signals must be connected to the users ext...

Page 10: ...Trigger Ready Indicates when the camera will accept a trigger signal Trigger Input A relay of the trigger input signal used to daisy chain the trigger signal for multiple cameras Readout Valid when c...

Page 11: ...cept an input voltage range of 5V to 17V DC Cameras designated as C with serial numbers 02 2xxxC xxxxx and later versions can accept an input voltage range of 5V to 24V DC However the suggested nomina...

Page 12: ...ilter carefully using a 2 5mm hex wrench Clean both sides of the IR filter using the same techniques as explained below for the sensor window DO NOT TOUCH ANY OPTICS WITH FINGERS OIL FROM FINGERS CAN...

Page 13: ...T REQUIRE ADJUSTING If for some reason the F mount requires adjustment use the following method Attach F mount compatible lens Use an F mount compatible lens that allows an infinity focus Attach the l...

Page 14: ...the F mount front assembly to the camera body Image to Infinity Set the lens to infinity and image a distant object The distance required will depend on the lens used but typically 30 to 50 feet shou...

Page 15: ...es however typical Jumbo Frames are around 9000 bytes Frame size is the number of bytes per packet and the larger the frame size the less the computer CPU will be loaded due to the processing of incom...

Page 16: ...t came with the network card o Once the driver is installed open the Network Connections Dialog as follows From the Windows desktop select start then select Control Panel then double click on the Netw...

Page 17: ...IP address of 169 254 x y where x and y can be any number Press the TAB key after entering the IP address and the subnet mask will automatically be entered The subnet mask is 255 255 0 0 Click OK to s...

Page 18: ...ble lengths must not exceed 100 meters Power Connection The camera requires a 12V DC power supply that can source a minimum of 600 mA of current See the Connections section of this document for more i...

Page 19: ...ecognized If the camera does not appear in the Viewer list after approximately 10 seconds then try disconnecting and reconnecting the power If it still does not appear restart the viewer If it still d...

Page 20: ...anel then double click on the Network Connections icon Double click the relevant network card listed or right click the relevant network card and select Properties This will open the properties window...

Page 21: ...If the list contains a property called Receive Descriptors then change this value to its maximum value Select OK to save properties o From the main properties dialog as in Figure 9 make sure that onl...

Page 22: ...cabling known to work Configure your NIC as outlined in Gigabit Ethernet Setup For Windows It should have an IP address of 169 254 x x Subnet Mask 255 255 0 0 This is the AutoIP address range If your...

Page 23: ...ame subnet as your NIC Camera is not listed or flashing Camera Unavailable There may be multiple NICs on your system set to the same subnet The camera can not know which card to resolve to Change the...

Page 24: ...re trigger event to capture frames Packets are incoming but all dropping Be sure you have JumboFrames enabled on your NIC Otherwise decrease your PacketSize setting to 1500 All packets completing as n...

Page 25: ...GE4000 User Manual 70 0030A D AVT Inc 23 Addendum...

Page 26: ...4 5 6 7 8 9 10 11 12 13 14 15 16 VDD1 GND1 IN1 IN2 OUT3 OUT4 NC GND1 GND2 NC IN4 IN3 OUT2 OUT1 GND2 VDD2 ISO TXD ISO 5V GALVANIC ISOLATION BOUNDARY ISOLATED 5V POWER RS 232 TXD SYNC OUT 3 LOGIC SYNC...

Page 27: ...TL RECEIVER USERS TRIGGER CIRCUIT CABLE SIDE SYNC OUT 3 1 2 3 4 5 6 7 8 9 10 11 12 HIROSE HR10A 10P 12P 1 2 3 4 5 6 7 8 9 10 11 12 The trigger circuit is connected to a Texas Instruments SN74ACT244PWR...

Page 28: ...V TTL DRIVER SYNC OUT 1 5V TTL RECEIVER The trigger circuit is connected to a Texas Instruments SN74ACT244PWR buffer driver inside the camera The required trigger input current is less than 10uA and t...

Page 29: ...B AVT Inc 27 Trigger Timing Diagram User Trigger Logic Trigger Exposure Readout Trigger Ready Imaging Tpd Trigger Latency Interline Time Expose Start Delay Trigger Jitter Idle Registered Exposure Tim...

Page 30: ...when the next Exposure cycle can begin such that the Exposure will end after the current Readout o Interline Time is the time between sensor row readout cycles o Imaging is high when the camera image...

Page 31: ...iggering cycle time whereby the camera image sensor is exposing and reading out simultaneously then the User Trigger signal should be applied as soon as a valid Trigger Ready is detected o In this cas...