C613-50170-01 Rev B
Command Reference for x510 Series
2169
AlliedWare Plus™ Operating System - Version 5.4.7-1.x
E
THERNET
P
ROTECTION
S
WITCHED
R
ING
(EPSR
ING
™) C
OMMANDS
SHOW
EPSR
CONFIG
-
CHECK
show epsr config-check
Overview
This command checks the configuration of a specified EPSR instance, or all EPSR
instances.
If an instance is enabled, this command will check for the following errors or
warnings:
•
The control VLAN has the wrong number of ports.
•
There are no data VLANs.
•
Some of the data VLANs are not assigned to the ring ports.
•
The failover time is less than 5 seconds for a stacked device.
•
The instance is a master with its secondary port on a common segment.
Syntax
show epsr [
<instance>
] config-check
Mode
User Exec and Privileged Exec
Example
To check the configuration of all EPSR instances and display the results, use the
command:
awplus#
show epsr config-check
Related
Commands
Parameter
Description
<
instance
>
Name of the EPSR instance to check on.
Table 52-1: Example output from
show epsr config-check
EPSR Status Description
Instance
----------------------------------------------------------------------------
red Warning Failover time is 2s but should be 5s because
device is stacked.
white OK.
blue Warning Primary port is not in data VLANs 29-99.
orange OK.
Don't forget to check that this node's configuration is consistant with all
other nodes in the ring.
----------------------------------------------------------------------------