AT-x950-28XSQ Switch and VCStack Installation Guide
127
Starting a Local Management Session
This procedure explains how to start a local management session on the
switch. It assumes that you powered on the device and waited two minutes
for it to initialize its operating software.
Note
The initial management session has to be a local session because
the AlliedWare Plus operating software does not have a default IP
address.
To start a local management session, perform the following procedure:
1. Connect the RJ-45 end of the management card included with the
switch to the Console RS-232 port on the management panel. Refer to
Figure 77.
Figure 77. Connecting the Management Cable to the Console RS-232 Port
2. Connect the other end of the cable to an RS-232 port on a terminal or
personal computer with a terminal emulation program.
3. Configure the VT-100 terminal or terminal emulation program as
follows:
Baud rate: 115200 bps
Data bits: 8