USA Headquarters
|
19800 North Creek Parkway
|
Suite 200
|
Bothell
|
WA 98011
|
USA
|
T: +1 800 424 4284
|
F: +1 425 481 3895
European Headquarters
|
Via Motta 24
|
6830 Chiasso
|
Switzerland
|
T: +41 91 69769.00
|
F: +41 91 69769.11
Asia-Pacific Headquarters
|
11 Tai Seng Link
|
Singapore
|
534182
|
T: +65 6383 3832
|
F: +65 6383 3830
www.alliedtelesis.com
© 2006 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.
617-000048 Rev. D
ADSL24A
| AT-TN121-A 24 Port ADSL2+ Service Module (Annex A)
ADSL24A
Model
Description
Part #
ADSL24A
24 ports, ADSL2+ Service Module, Annex A
AT-TN-121-A
Ordering Information
Interface Specifications
Number of ports:
24
Backplane capacity:
1Gbps
Physical design:
Front Access
RJ-21 (Female)
ADSL Standards
ITU-T G.992.1 (ADSL, G.DMT, T1.413)
ITU-T G.992.5 (ADSL2+)
S = 1/2
Annex A (ONLY)
Port Specifications
Number of VCs per port:
4
Priority queues per VC:
8
Dropped packet counter
Full traffic classifier support
Full traffic classifier action support
ARP Filtering
Ingress Metering:
1Mbps increment
Peak Cell Rate Limiting per VC
Ingress Max Burst Size:
64kbps
Egress Max Burst Size:
64kbps
Protocols and Specifications
IEEE 802.1Q VLAN Bridging
IEEE 802.1p Prioritization
IETF RFC 1112 IP Multicasting/IGMP Snooping v1
IETF RFC 2236 IP Multicasting/IGMP Snooping v2
DHCP Relay Agent option 82 (RFC 3046)
Power Requirements
Maximum Power:
45W
Environmental Specifications
Operating Temp:
-40C to 65C
Storage Temp:
-40C to 75C
Relative Humidity:
5% to 95%, non-condensing
Regulatory Approvals
FCC Part 15 Class A/ANSI C63.4
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
VCCI Class A; ITE/ CISPR 22:1997 Class A
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
EN 300 386 V1.3.1:2001-09/EN 61000-4-3:1998
EN 300 386 V1.3.1:2001-09/EN 6100-4-6:1996
EN 300 386 V1.3.1:2001-09/EN 61000-4-4:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-5:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-2:1999
UL/cUL 60950: IEC60950
NEBS Level 3, GR-1089 Issue 3, GR63 Issue 2
USDA RUS
iMAP 9x00 Chassis
Model
Description
Part #
iMAP 9700
17-slot chassis with DC power with faceplates
AT-TN-250GF
iMAP 9700
17-slot chassis with DC power without faceplates
AT-TN-250G
iMAP 9400
7-slot chassis with DC power with faceplates
AT-TN-251GF
iMAP 9400
7-slot chassis with DC power without faceplates
AT-TN-251G
MiniMAP 9101
3-slot mini chassis with DC power
AT-TN-9101-A-80
MiniMAP 9102
3-slot mini chassis with AC power
AT-TN-9102-A-XX*
iMAP Common Control
Model
Description
Part #
CFC24
24GbE switch controller card
AT-TN-401-B
GE3
3x GbE WAN interface card
AT-TN-301-A
CFC12
12GbE switch controller card
AT-TN-408-A
Related ADSL2+ CPE
Model
Description
Part #
RG624
ADSL2+ intelligent Multiservice Gateway,
4 x LAN (Annex A) intelligent
AT-RG624A
RG634
ADSL2+ intelligent Multiservice Gateway,
4 x LAN, 2 x FXS (Annex A)
AT-RG634A
RG644
ADSL2+ intelligent Multiservice Gateway,
4 x LAN, 1 x ISDN BRI (Annex A)
AT-RG644A
ADSL2+ Modem
ADSL2+ Modem, 1 x LAN (Annex A)
COR-DSL200A
*Where XX
= 10 for U.S. power cord
= 30 for U.K. power cord
= 40 for Australia power cord
= 50 for Europe power cord