background image

USA Headquarters 

|

19800 North Creek Parkway 

|

Suite 100 

|

Bothell 

|

WA 98011 

|

USA 

|

T: +1 800 424 4284 

|

F: +1 425 481 3895

European Headquarters 

|

Via Motta 24 

|

6830 Chiasso 

|

Switzerland 

|

T: +41 91 69769.00 

|

F: +41 91 69769.11

Asia-Pacific Headquarters 

|

11 Tai Seng Link 

|

Singapore 

|

534182 

|

T: +65 6383 3832 

|

F: +65 6383 3830

www.alliedtelesis.com

© 2008 Allied Telesis Inc. All rights reserved. Information in this document is subject to change without notice. All company names, logos, and product designs that are trademarks or registered trademarks are the property of their respective owners.

617-000113  Rev. D

EPON2 

| AT-TN118-A 2 Port EPON Service Module

EPON2

Model

Description

Part #

EPON2

2 ports, EPON service module

AT-TN-118-A

Ordering Information

Interface Specifications

Number of PON ports:

2

Number of subscribers per PON: 32
Backplane capacity:

2Gbps

Physical design:

Front access
SFP optics 

EPON Standards 

IEEE 802.3ah EFM TM-2004
IEEE 802.3ah EFM PON clause 64 
IEEE 802.3ah OAM clause 57
IEEE 802.3ah optics clause 60

Port Specifications

Priority queues per port:

8

RMON counters
Traffic classifier support
Traffic classifier action support
User configurable per VLAN SLA

Protocols and Specifications

IEEE 802.1Q VLAN bridging
IEEE 802.1p prioritization
IETF RFC 1112 IP Multicasting/IGMP snooping v1
IETF RFC 2236 IP Multicasting/IGMP snooping v2
DHCP Relay Agent option 82 (RFC 3046)

Power Requirements

Maximum power:

25W

Environmental Specifications

Operating temp:

-5ºC to 55ºC

Storage temp:

-40ºC to 75ºC

Relative humidity:

5% to 95%, non-condensing

Regulatory Approvals

FCC Part 15 Class A/ANSI C63.4
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
VCCI Class A; ITE/ CISPR 22:1997 Class A
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
EN 300 386 V1.3.1:2001-09/EN 61000-4-3:1998
EN 300 386 V1.3.1:2001-09/EN 6100-4-6:1996
EN 300 386 V1.3.1:2001-09/EN 61000-4-4:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-5:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-2:1999
UL/cUL 60950: IEC60950
NEBS Level 3, GR-1089 Issue 3, GR63 Issue 2
USDA RUS

iMAP 9x00 Chassis

Model

Description

Part #

iMAP 9700    

17-slot chassis with DC power without faceplates

AT-TN-250G-B

iMAP 9400   

7-slot chassis with DC power without faceplates

AT-TN-251G

MiniMAP 9101   

3-slot mini chassis with DC power

AT-TN-9101-A-80

MiniMAP 9102

3-slot mini chassis with AC power

AT-TN-9102-A-xx*

iMAP Common Control

Model

Description

Part #

CFC24   

24GbE switch controller card 

AT-TN-401-C

GE3    

3 x GbE WAN interface card

AT-TN-301-C

CFC12   

12GbE switch controller card

AT-TN-408-A

CFC56

56GbE switch controller card

AT-TN-407-B

XE1

1 x 10GbE WAN interface card

AT-TN-308-A

*Where XX = 10 for U.S. power cord

30 for U.K. power cord

40 for Australian power cord
50 for European power cord

Related iMAP Accessories

Model

Description

Part #

EPON SFP   

SFP BiDi, 20km, burst

AT-SPBD20B-14

Filler    

Full size service slot filler plate

AT-TN-M000-A

Related EPON CPE

Model

Description

Part #

EPON ONU

Outdoor ONU supporting Voice, Video, Data

Please see 
AT-iMG646MOD
datasheet

Allied Telesis’ iMAP family of 
integrated Multiservice Access Platforms

Reviews: