8

AT-PWR01 & AT-PWR01-80

C613-04049-01 REV B

 

If the PSU does not function as expected, follow these steps:

1.

Check all cable connections are correct and secure.

2.

For DC models, check that the standby switch has been pressed and is in the 
ON position.

For AC models, check the PSU is receiving the correct AC voltage.

3.

If the LEDs indicate a PSU fault, replace the PSU or have it serviced by 
authorised service personnel. 

More troubleshooting information can be found in the 

AT-8900 Series Hardware 

Reference

.

Table 3: PSU LEDs found on all AT-8900 Series switches

PSU 1

Green

PSU 1 is installed and supplying power to the 
switch, and the voltage output is within 
specification.

Red

PSU 1 is installed in the switch, a fan has failed, 
or the PSU has exceeded its recommend 
temperature threshold of 75º C (167º F).

A FOM is installed in the switch and a fan has 
failed.

The bay is empty (no PSU or FOM installed).

Not lit

A FOM is installed and the fan is good.

PSU 2

Green

PSU 2 is installed and supplying power to the 
switch, and the voltage output is within 
specification.

Red

PSU 2 is installed in the switch, a fan has failed, 
or the PSU has exceeded its recommend 
temperature threshold of 75º C (167º F).

A FOM is installed in the switch and a fan has 
failed.

The bay is empty (no PSU or FOM installed).

Not lit

A FOM is installed and the fan is good.

Summary of Contents for AT-PWR01

Page 1: ...AT PWR01 QUICK INSTALL GUIDE ...

Page 2: ... in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein e...

Page 3: ...t pre installed in a AT 8900 Series switch at the factory Contact your sales representative if any items are damaged or missing One AC power cord AC model One power cord retaining clip AC model One Safety and Statutory Information booklet One warranty card AT 8900 Series Printed Acrobat PDF Website Documentation Roadmap AT 8900 Series Safety and Statutory Information Booklet AT 8900 Series Softwar...

Page 4: ... nz support at8900 2 Gather the tools and equipment you will need To loosen or secure the PSU s mounting screws you will need a Phillips 2 screwdriver To install a DC version of the PSU you will need an appropriate DC power source DC supply cable ring connectors and a crimp tool 3 Unpack the PSU In an antistatic environment remove the PSU from its packing material Be sure to observe ESD precaution...

Page 5: ...of the switch s power supply bay If you remove a PSU or FOM from the switch replace the PSU or FOM to prevent dust and debris from entering the switch chassis and to maintain proper airflow 6 Insert a PSU Slowly and carefully slide the PSU into the switch s power supply bay Firmly press the PSU home until its front panel engages or nearly engages the switch chassis 7 Secure the PSU Keep the PSU in...

Page 6: ...stalled only in Restricted Access Areas Dedicated Equipment Rooms Equipment Closets or the like in accordance with Articles 110 16 110 17 and 110 18 of the National Electrical Code ANSI NAPA 70 DC supply cable specifications Three core cable is required Minimum core size 3 3 mm2 12 AWG high strand count copper wire Minimum cable rating 600 V 90 degrees Celsius DC power supply specifications 40 to ...

Page 7: ...cable 8 Ensure the circuit breaker for the supply circuit and the Run Standby switch on the switch are in the OFF position 9 Connect the supply cable wires to the circuit breaker 10 Switch the power switch to the ON position 9 Check the PSU LEDs Each PSU has LEDs that indicate the PSU s operational status Once you have inserted the PSUs and powered on the chassis check the LEDs for correct operati...

Page 8: ...Green PSU 1 is installed and supplying power to the switch and the voltage output is within specification Red PSU 1 is installed in the switch a fan has failed or the PSU has exceeded its recommend temperature threshold of 75º C 167º F A FOM is installed in the switch and a fan has failed The bay is empty no PSU or FOM installed Not lit A FOM is installed and the fan is good PSU 2 Green PSU 2 is i...

Page 9: ...ortant safety information and statutory declarations for AT 8900 Series switches The AT 8900 Series Quick Install Guide which outlines the procedure for installing a AT 8900 Series switch The AT 8900 Series Hardware Reference which includes detailed hardware specifications for the AT 8900 Series switch The AT 8900 Series Software Reference which provides detailed information on configuring the AT ...

Reviews: