Installation
40
Setting the
Subscriber Unit
DIP Switches
1. Set DIP switch 1 to the Up (CPE) position as shown in Figure 11. This
configures the media converter as a Subscriber unit.
Figure 11. Subscriber Unit DIP Switch Position
2. Set DIP switch 5 to the desired SML setting:
The Up (ON) position enables SML.
The Down (OFF) position disables SML.
Note
Go to “Smart Missing Link (SML) Configuration” on page 30 and
“Smart MissingLink™ (SML)” on page 31 for an overview more
information concerning this feature.
Note
DIP switches 2 - 4 configure the VDSL profile and are only active on
the Provider unit. The VDSL DIP switch settings on the Subscriber
unit are inactive.
3. Go to “Cabling the Subscriber Unit”.
Cabling the
Subscriber Unit
To install the cables for the Subscriber unit, perform the following steps:
1. Connect an Ethernet cable from the RJ-45 Ethernet port to the
Ethernet port on your computer, as shown in Figure 12.
Subscriber
(Up position)