Chapter 1: Overview
30
Network Topologies
Standalone Topology
A standalone topology uses only one bridging converter between the end-
nodes. Figure 8 illustrates a standalone topology that uses two
AT-GS2002/SP bridging converters to interconnect three remote
campuses. Campus 1 has an AT-9424T/SP switch which provides a
connection of up to 15 kilometers (9.3 miles), are connected to two
AT-GS2002/SP bridging converters via their 1000Base SFP ports. The
10/100/1000Base-T twisted pair port on the first bridging converter is
connected to one of the twisted pair ports in the AT-8524M switch at
Campus 2; and the 10/100/1000Base-T twisted pair port on the second
bridging converter is connected to one of the twisted pair ports in the
AT-8524M switch at Campus 3.
Figure 8. Standalone Topology
1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
LINK
MODE
LINK
MODE
COL
100
FULL
ACT
FAULT
RP
S
MA
S
TER
PWR
MODE
1
3
5
7
9
11
2
4
6
8
10
12
13
15
17
19
21
23
14
16
18
20
22
24
S
TATU
S
26
25
AT-8524M Fa
s
t Ethernet
S
witch
1
3
5
7
9
11
13
15
17
19
21
23
2
4
6
8
10
12
14
16
18
20
22
24
LINK
MODE
LINK
MODE
COL
100
FULL
ACT
FAULT
RP
S
MA
S
TER
PWR
MODE
1
3
5
7
9
11
2
4
6
8
10
12
13
15
17
19
21
23
14
16
18
20
22
24
S
TATU
S
26
25
AT-8524M Fa
s
t Ethernet
S
witch
FAULT
RP
S
MA
S
TER
POWER
CLASS 1
LASER PRODUCT
S
TATU
S
TERMINAL
PORT
1
3
5
7
9
11
2
4
6
8
10
12
13
15
17
19
21
23R
14
16
18
20
22
24R
AT-9424T/
S
P
Gigabit Ethernet
S
witch
1
3
5
7
9
11
13
15
17
19
21 23R
2
4
6
8
10
12
14
16
18
20
22 24R
23
24
L/A
D/C
D/C
L/A
D/C
L/A
1000 LINK / ACT
HDX / COL
FDX
10/100 LINK / ACT
PORT ACTIVITY
L/A
1000 LINK / ACT
S
FP
S
FP
24
S
FP
23
AT-G
S
2002/
S
P
GIGABIT BRIDGING CONVERTER
LINK
ACT
CLASS 1
LASER PRODUCT
1000Ba
s
e
ML
S
ML
LT
MODE
10/100/1000 Ba
s
e-T
PWR
AN
1000M
LINK
ACT
100M
PORT 2
PORT 1
S
FP
AUTO MDI/MDI-X
AT-G
S
2002/
S
P
GIGABIT BRIDGING CONVERTER
LINK
ACT
CLASS 1
LASER PRODUCT
1000Ba
s
e
ML
S
ML
LT
MODE
10/100/1000 Ba
s
e-T
PWR
AN
1000M
LINK
ACT
100M
PORT 2
PORT 1
S
FP
AUTO MDI/MDI-X
3
57
Campus 1: AT-9424T/SP
15 km (9.32 mi)
AT-GS2002/SP
Campus 2: AT-8524M
Twisted Pair
AT-GS2002/SP
100 m (328 ft) maximum
Multi-mode
Fiber Optic
Campus 3: AT-8524M
100 m (328 ft) maximum
15 km (9.32 mi)
Summary of Contents for AT-GS2002 Series
Page 1: ...AT GS2002 AT GS2002 SP Gigabit Bridging Converters Installation Guide PN 613 50648 00 Rev A...
Page 8: ......
Page 32: ......
Page 58: ......
Page 64: ......
Page 91: ...AT GS2002 Series Installation Guide 91 1 1 2 3 LAN 4 5 6 I 7 8 9 40 C...
Page 93: ...AT GS2002 Series Installation Guide 93 20 21 22 23 24 25 26 UL 600 90 C 14 AWG 27 28 29...
Page 95: ...AT GS2002 Series Installation Guide 95 41 42 TEL PSTN 43 26 AWG...
Page 96: ......