Pinout Assignments

Figure 8 shows the pin assignments of the RJ-45 connector.

Figure 8  

RJ-45 Connector

Table 4 lists the 100Base-TX connector pins and their signals when the port is 
operating in either MDI or MDI-X configuration.

Table 4  

RJ-45 Pin Signals

MDI-X (Default)

Signal

MDI

Signal

1

RX+

1

TX+

2

RX-

2

TX-

3

TX+

3

RX+

4

-

4

-

5

-

5

-

6

TX-

6

RX-

7

-

7

-

8

-

8

-

8

8

1

1

Summary of Contents for AT-FS724L

Page 1: ...AT FS724L Fast Ethernet Switch Installation Guide PN 613 50464 00 Rev A...

Page 2: ...their respective owners Allied Telesyn Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided...

Page 3: ...harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful...

Page 4: ...contient les instructions de s curit relatives l installation de cet quipement Lorsque vous voyez le symbole reportez vous l annexe B pour consulter la traduction de ces instructions dans votre langue...

Page 5: ...on viii Chapter 1 Overview 1 Key Features 2 Status LEDs 3 Twisted Pair Ports 3 Port Speed 3 Duplex Mode 4 Auto MDI MDI X 4 MAC Address Table 5 Store and Forward 6 Backpressure and Flow Control 6 Inter...

Page 6: ...i Chapter 3 Troubleshooting 19 Appendix A Technical Specifications 21 Physical 21 Environmental 21 Electrical Rating 22 Agency Compliance 22 Pinout Assignments 23 Appendix A Translated Safety and Emis...

Page 7: ...al information for all of our products For product guides select Support Services from our web site Document Conventions This guide uses the following conventions Note Notes provide additional informa...

Page 8: ...nical Support via E mail or telephone refer to the Support Services section of the Allied Telesyn web site http www alliedtelesyn com Returning Products Products for return or repair must first be ass...

Page 9: ...are designed for desktop or rackmount installation These switches are easy to install and do not require software configuration or management Figure 1 illustrates the front panel of the AT FS724L swit...

Page 10: ...s Auto Negotiation on all ports IEEE 802 3u compliant Store and forward switching mode Backpressure and flow control IEEE 802 3x compliant Store and forward packet handling Storage for up to 4 000 MAC...

Page 11: ...port speed automatically With Auto Negotiation the speed of the ports are set automatically by the switch after it determines the speed of the end node connected to the port Auto Negotiation is desig...

Page 12: ...FS724L switch to successfully Auto Negotiate its duplex mode with an end node the end node should also be using Auto Negotiation Otherwise a duplex mode mismatch can occur The twisted pair port using...

Page 13: ...number on which the frame was received The result is a table that contains a list of all the MAC addresses of end nodes that have sent frames to the switch and the ports on the switch to which the end...

Page 14: ...a between the end nodes might need to instruct the faster end node to stop transmitting data to allow the slower end node to catch up An example of this would be when a server operating at 100 Mbps is...

Page 15: ...itching power supply operating at 100 120 200 240V AC The frequencies are 50 60 Hz 0 5A at all input voltage 3 Allied Telesyn ships power cords with these units to the U S Continental Europe and the U...

Page 16: ...lows each end node to directly connect to a 10 100Base TX port on an AT FS724L switch This gives each end node a dedicated 10 Mbps or 100 Mbps link Figure 2 Power Workgroup Topology AT FS724L 24 Port...

Page 17: ...switch Since Port 24 is wired as auto MDI MDI X a crossover or straight through Category 5 or better twisted pair cable can be used Figure 3 Cascade Topology AT FS724L 24 Port Fast Ethernet Switch 18...

Page 18: ......

Page 19: ...items are included in your package If any item is missing or damaged contact your Allied Telesyn sales representative for assistance One AT FS724L Fast Ethernet Switch Four protective feet for desktop...

Page 20: ...guidelines when selecting a site for your switch Select a site that is dust free and moisture free Select a site that will allow you to easily access the switch s power and data cables The twisted pai...

Page 21: ...on equipment or cables during periods of lightning activity 6 Caution Power Cord The power cord is used as a disconnection device to de energize equipment disconnect the power cord 7 Caution Pluggable...

Page 22: ...o the switch by plugging the AC DC power adapter into an AC power outlet then plug the DC connector to the power receptacle located on the back of the switch 5 Verify that the POWER LED is green If th...

Page 23: ...on page 14 To install an AT FS724L in a rack perform the following procedure 1 If attached remove the four protective feet from the bottom of the switch as shown in Figure 5 Figure 5 Removing the Rubb...

Page 24: ...fy that the POWER LED is green If the LED is OFF refer to Troubleshooting on page 19 Note The switch performs a self diagnostic test upon power up This takes about 20 seconds to complete 6 Connect the...

Page 25: ...FS724L Fast Ethernet Switch Installation Guide 17 Warranty Registration When you finish installing the product you should register you product by completing the enclosed warranty card and sending it...

Page 26: ......

Page 27: ...power adapter or power cord depending on your model If a LINK ACTIVITY LED is OFF do the following Check that the end node connected to the port is powered ON and is operating properly Check that the...

Page 28: ......

Page 29: ...1 72 in Weight 2 5 kg 5 5 lbs Environmental Maximum Operating 0 to 40 C 32 to 104 F Maximum Storage 25 to 70 C 13 F to 158 F Relative Humidity Operating 5 to 80 non condensing Relative Humidity Stora...

Page 30: ...Electrical Rating Internal Universal Power Supply 100 240 V AC 50 60 Hz 0 5A input Agency Compliance EMI RFI FCC Class B EN55022 Class B VCCI Class B CISPR Class B Electrical Safety EN60950 TUV UL 60...

Page 31: ...ments of the RJ 45 connector Figure 8 RJ 45 Connector Table 4 lists the 100Base TX connector pins and their signals when the port is operating in either MDI or MDI X configuration Table 4 RJ 45 Pin Si...

Page 32: ......

Page 33: ...xe contient la traduction en plusieurs langues des instructions de s curit figurant dans ce guide T rke T m liite sis lt t ss oppaassa esiintyv t turvaohjeet usealla kielell Importante questa appendic...

Page 34: ...mful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful int...

Page 35: ...equipment or CABLES during periods of LIGHTNING ACTIVITY 7 Caution The power cord is used as a disconnection device to de energize equipment disconnect the power cord 8 Caution Pluggable equipment the...

Page 36: ...Gewitters ausf hren 7 Vorsicht Das netzkabel dient zum trennen der stromversorgung Zur trennung vom netz kabel aus der steckdose ziehen 8 Steckbares Ger t Die Anschlu buchse sollte in der N he der Ein...

Page 37: ...Uvejr Fare UNDLAD at arbejde p udstyr eller KABLER i perioder med LYNAKTIVITET 7 Waarschuwing Het toestel wordt uitgeschakeld door de stroomkabel te ontkoppelen Om het toestel stroomloos te maken de s...

Page 38: ...s eller afmonteres 6 Gevaar Voor Blikseminslag Gevaar NIET aan toestellen of KABELS WERKEN bij BLIKSEM 7 Attention Le cordon d alimentation sert de mise hors circuit Pour couper l alimentation du mat...

Page 39: ...re Danger NE PAS MANIER le mat riel ou les C BLES lors d activit orageuse 7 Attention Le cordon d alimentation sert de mise hors circuit Pour couper l alimentation du mat riel d brancher le cordon 8 E...

Page 40: ...N kaapelit 6 Salamaniskuvaara Engenvaara L TY SKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA 7 Huomautus VIRTAJOHTOA K YTET N VIRRANKATKAISULAITTEENA VIRTA KATKAISTAAN irrottamalla virt...

Page 41: ...o sui CAVI durante PRECIPITAZIONI TEMPORALESCHE 7 Attenzione Il cavo di alimentazione usato come dispositivo di disattivazione Per togliere la corrente al dispositivo staccare il cavo di alimentazione...

Page 42: ...frakobles 6 Fare For Lynnedslag Fare ARBEID IKKE p utstyr eller KABLER i TORDENV R 7 Forsiktig STR MLEDNINGEN BRUKES TIL FRAKOBLE UTSTYRET FOR DEAKTIVISERE UTSTYRET m str mforsyningen kobles fra 8 Uts...

Page 43: ...ento ou nos CABOS durante per odos suscet veis a QUEDAS DE RAIO 7 Cuidado O cabo de alimenta o utilizado como um dispositivo de desconex o Para deseletrificar o equipamento desconecte o cabo de alimen...

Page 44: ...NEXION en los equipos o en LOS CABLES durante TORMENTAS ELECTRICAS 7 Atencion EL CABLE DE ALIMENTACION SE USA COMO UN DISPOSITIVO DE DESCONEXION PARA DESACTIVAR EL EQUIPO desconecte el cable de alimen...

Page 45: ...J p utrustningen eller kablarna vid SKV DER 7 Varning N tkabeln anv nds som str mbrytare f r att koppla fr n str mmen dra ur n tkabeln 8 Utrustning Med Plugg Uttaget skall installeras i utrustningens...

Page 46: ......

Reviews: