Page 1: ...AT FS716 AT FS716E AT FS724I Fast Ethernet Switches Installation Guide PN 613 10804 00 Rev A...

Page 2: ...respective owners Allied Telesyn International Corp reserves the right to make changes in specifications and other information contained in this document without prior written notice The information p...

Page 3: ...th the limits for a Class A digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a...

Page 4: ...ission d interf rences radio lectriques EN55022 Classe A MISEENGARDE dansunenvironnementdomestique ceproduitpeutprovoquerdesinterf rences radio lectriques Auquel cas l utilisateur devra prendre les me...

Page 5: ...na radiorrecep o e neste caso pode ser necess rio que o utente tome as medidas adequadas Imunidade EN50082 1 Seguran a El ctrica TUV EN60950 UL1950 CSA 950 EST NDARES Este producto cumple con los sig...

Page 6: ...Y Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection again...

Page 7: ...trische Veiligheid TUV EN60950 UL1950 CSA 950 NORMES ce produit est conforme aux normes de suivantes Emission d interf rences radio lectriques EN55022 Classe B Immunit EN50082 1 S curit lectrique TUV...

Page 8: ...22 Classe B Imunidade EN50082 1 Seguran a El ctrica TUV EN60950 UL1950 CSA 950 EST NDARES Este producto cumple con los siguientes est ndares Emisi n RFI EN55022 Clase B Inmunidad EN50082 1 Seguridad e...

Page 9: ...ated 6 amp minimum 250V made of HAR cordage molded IEC 320 connector on one end and on the other end a plug approved by the country of end use CAUTION Air vents must not be blocked and must have free...

Page 10: ...for ELEKTRISK ST D afbrydes den elektriske str m til produktet f r LAN kablerne monteres eller afmonteres FARE UNDER UVEJR FARE UNDLAD at arbejde p udstyr eller KABLER i perioder med LYNAKTIVITET INST...

Page 11: ...EKTRISCHE SNOEREN Gebruik een elektrisch snoer maximum 4 5 meter lang berekend voor ten minste 6 amp re 250 V uit HAR vervaardigd met aan het ene uiteinde een gevormd IEC 320 aansluitstuk en aan het a...

Page 12: ...ytt j n huollettavissa olevia osia T m laite sis lt VAARALLISIA J NNITTEIT ja sen voi avata vain koulutettu ja p tev teknikko V ltt ksesi S HK ISKUN mahdollisuuden katkaise s hk virta tuotteeseen enne...

Page 13: ...e pericolosa su parti metalliche accessibili ELETTRICIT AVVERTENZA SUL CAVO Usare un cavo della lunghezza massima di metri 4 5 con capacit minima di 6 A 250 V di filo HAR dotato di connettore stampato...

Page 14: ...e o aparelho da fonte de energia el trica antes de conectar e desconectar os cabos da LAN PERIGO DE CHOQUE CAUSADO POR RAIO PERIGO N O TRABALHE no equipamento ou nos CABOS durante per odos suscet veis...

Page 15: ...250 V hecho de cable HAR con el conector moldeado IEC 320 en un extremo y con un enchufe que est aprobado por el pa s de uso final en el otro ATENCION Las aberturas para ventilaci n no deber n bloquea...

Page 16: ...20 kontaktdon i ena nden och i den andra en plugg som godk nts i landet d r produkten anv nds VARNING Luftventilerna f r ej blockeras och m ste ha fri tillg ng till omgivande rumsluft f r avsvalning D...

Page 17: ...l Description 3 Front Panel LEDs 3 MDI MDI X Port 4 Power Supply 5 Required Voltage 5 Auto Negotiation 5 Chapter 2 Installation 7 Before you Proceed 7 Verifying Package Contents 7 Site Requirements 8...

Page 18: ...l Specifications 18 UTP RJ45 Connector 18 Network Specifications 19 100Base TX Cable 19 100Base TX Connector Pinouts 20 Straight through Cable 20 Crossover Cable 20 Appendix B Technical Support Fax Or...

Page 19: ...Models and Port Description Model Description AT FS716 16 auto negotiating 10 100 Mbps twisted pair RJ45 ports Port 16 with MDI MDI X push button Internal Power Supply AT FS716E 16 auto negotiating 10...

Page 20: ...00 Mbps ports Media dependent interface MDI push button setting for hub connection or MDI X push button setting for PC connection on Port 16 24 Support for up to 8K MAC addresses Internal power supply...

Page 21: ...ion The physical description for the switches includes Media Dependent Interface MDI MDI X push button setting Port 16 or Port 24 LEDs Power supply Front Panel LEDs Figure 2 shows the layout of the fr...

Page 22: ...iption POWER Green Off means there is no power to the switch On means there is power to the switch LINK ACTIVITY Green On indicates a valid physical link on the port Blinking indicates data is being t...

Page 23: ...es switches to automatically exchange information over a link about their speed and duplex abilities This allows devices to perform automatic configurations to achieve the maximum common level of oper...

Page 24: ......

Page 25: ...e sure that the package includes the following items One AT FS716 AT FS716E or AT FS724I switch One AC power cord AT FS716 or AT FS724I or power adapter AT FS716E Two rackmounting brackets with screws...

Page 26: ...ktop Installation Place the switch on the desktop using these steps or perform the steps Rackmount Installation on page 9 1 Attach the four self adhesive rubber feet to the bottom of the switch positi...

Page 27: ...n the switch in a standard 19 inch rack and secure the switch s brackets to the rack using the 4 large screws provided 5 Plug the power cord into the power receptacle Make sure the 3RZHU LED on the fr...

Page 28: ...ether using any of the switch ports provided you maintain the same medium type Two switches can be cascaded to support multiple network port connections Cable length to the nodes must follow the 100Ba...

Page 29: ...de 11 Figure 4 Cascading Switches 3 Check the front panels to make sure that the green LQN FWLYLW LED lights Uplink Configuration For 100 Mbps connection to the backbone use Port 16 24 with the switch...

Page 30: ......

Page 31: ...imately 1 3 seconds for the auto negotiation process to complete after power on or after the cables are reconnected 3 Make sure the Link Activity and other LEDs of both switch ports are lit 4 After co...

Page 32: ...of the unit Is the Link Activity LED lit The Link LED on the front of the switch lights when a proper connection between the corresponding 10 100Base TX port and the equipment connected to it is estab...

Page 33: ...I X push button setting for Port 16 24 Use MDI for uplink MDI X for a PC 4 Problem 4 There is data loss between the switch and one of the connected network nodes Solution 4 Make sure that the distance...

Page 34: ......

Page 35: ...16 4 75 lbs 2 16 kg AT FS716E 4 4 lbs 2 0 kg AT FS724I 5 5 lbs 2 5 kg Operating temperatures 0 to 40 C 32 to 104 F Storage temperatures 40 to 70 C 40 to 158 F Relative humidity 5 to 95 non condensing...

Page 36: ...tch and network node connections Electrical Specifications AT FS716 or AT FS724I Internal Power Internal universal power supply with 100 to 240 VAC 50 60 Hz 0 3 A input AT FS716E External Power Extern...

Page 37: ...bles If voice quality cables are used in a 100Base TX network system data movement may be slow collision prone or non existent In addition interface LEDs will usually indicate a valid link in such cas...

Page 38: ...Switch Specifications 20 100Base TX Connector Pinouts Straight through Cable Crossover Cable 4 7 7 4 5 0 9 9 5 0 7 0 5 6 5 5 6 5 7 0 4 7 7 4 5 0 9 9 5 0 7 0 5 6 5 5 6 5 7 0...