background image

iv

Electrical Safety and Installation Requirements

ELECTRICAL—TYPE CLASS 1 EQUIPMENT
THIS EQUIPMENT MUST BE EARTHED.  Power plug must be connected to a properly  wired earth 
ground  socket outlet. An improperly wired socket outlet could place  hazardous voltages on 
accessible metal parts.  

ELECTRICAL—CORD NOTICE
Use power cord, maximum 4.5 meters long, rated 6 amp minimum, 250V, made of HAR  cordage  
molded IEC 320 connector on one end and on the other end a plug approved  by the country of end 
use.

CAUTION: Air vents must not be blocked and must have free access to the room  ambient  air for 
cooling.

OPERATING TEMPERATURE 
This product is designed for a maximum ambient temperature of 40 degrees C.

ALL COUNTRIES: Install product in accordance with local and National Electrical Codes.

NORMEN: Dieses Produkt erfüllt die Anforderungen der nachfolgenden Normen.

WARNUNG: Bei Verwendung zu Hause kann dieses Produkt Funkstörungen hervorrufen.  In 
diesem Fall müßte der Anwender angemessene Gegenmaßnahmen ergreifen.

Hochfrequenzstörung 

EN55022 Klasse A

WARNUNG: Dieses Produkt muß mit entstörten Kabeln versehen sein, damit es den 
Emissionsgrenzen der Klasse A entspricht. Wenn dieses Produkt nicht mit entstörten Kabeln 
verwendet wird, könnte es Funkstörungen hervorrufen; der Anwender müßte in diesem Fall 
angemessene Gegenmaßnahmen ergreifen.

Störsicherheit EN50082-1

SICHERHEIT
ACHTUNG
: GEFÄHRLICHE SPANNUNG
Das Gehäuse nicht öffnen. Das Gerät enthält keine vom Benutzer wartbaren Teile.  Das Gerät steht 
unter Hochspannung und darf nur von qualifiziertem technischem  Personal geöffnet werden. Vor 
Anschluß der LAN-Kabel, Gerät vom Netz trennen.

GEFAHR DURCH BLITZSCHLAG
GEFAHR
: Keine Arbeiten am Gerät oder an den Kabeln während eines Gewitters  ausführen.

INSTALLATION

AUTOMATISCHE SPANNUNGSEINSTELLUNG 
Dieses Gerät stellt sich automatisch auf die auf dem Etikett aufgeführten Spannungswerte ein.

GERÄTE DER KLASSE 1
DIESE GERÄTE MÜSSEN GEERDET SEIN. Der Netzstecker darf nur mit einer  vorschriftsmäßig 
geerdeten Steckdose verbunden werden. Ein unvorschriftsmäßiger  Anschluß kann die Metallteile 
des Gehauses unter gefährliche elektrische Spannungen  setzen.

NETZKABEL

Das Netzkabel sollte eine maximale Länge von 4,5 Metern, einen Nennwert von  mindestens 6 A 
und 250 V haben, aus HAR-Material hergestellt und mit einer gepreßten,  IEC 320 entsprechenden, 
Anschlußverbindung an einem Ende, und am anderen Ende mit  einem im Land des 
Endverbrauchers geprüften Stecker ausgestattet sein.

Summary of Contents for AT-FS704

Page 1: ...AT FS704 10 100 Fast Ethernet Unmanaged Switch Installation Guide PN 613 10778 00 Rev A...

Page 2: ...Allied Telesyn International Corp reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein is...

Page 3: ...TAGE ADJUSTMENT This product will automatically adjust to any voltage between the ranges shown on the label U S Federal Communications Commission RADIATED ENERGY Note This equipment has been tested an...

Page 4: ...nzen der Klasse A entspricht Wenn dieses Produkt nicht mit entst rten Kabeln verwendet wird k nnte es Funkst rungen hervorrufen der Anwender m te in diesem Fall angemessene Gegenma nahmen ergreifen St...

Page 5: ...enne enhed indeholder LIVSFARLIGE STR MSP NDINGER og b r kun bnes af en uddannet og kvalificeret tekniker For at undg risiko for ELEKTRISK ST D afbrydes den elektriske str m til produktet f r LAN kabl...

Page 6: ...oestel van de stroombron ontkoppelen alvorens de LAN kabels te koppelen of ontkoppelen GEVAAR VOOR BLIKSEMINSLAG GEVAAR NIET aan toestellen of KABELS WERKEN bij BLIKSEM INSTALLATIE ELEKTRISCH AUTOMATI...

Page 7: ...riel avant de connecter ou de d connecter les c bles LAN DANGER DE FOUDRE DANGER NE PAS MANIER le mat riel ou les C BLES lors d activit orageuse INSTALLATION R GLAGE DE TENSION AUTOMATIQUE LECTRIQUE...

Page 8: ...en katkaise s hk virta tuotteeseen ennen kuin liit t tai irrotat paikallisverkon LAN kaapelit SALAMANISKUVAARA HENGENVAARA L TY SKENTELE laitteiden tai KAAPELEIDEN KANSSA SALAMOINNIN AIKANA ASENNUS S...

Page 9: ...l dispositivo prima di collegare o staccare i cavi LAN PERICOLO DI FULMINI PERICOLO NON LAVORARE sul dispositivo o sui CAVI durante PRECIPITAZIONI TEMPORALESCHE INSTALLAZIONE ELETTRICIT REGOLAZIONE AU...

Page 10: ...mmen til produktet v re avsl tt f r LAN kablene til eller frakobles FARE FOR LYNNEDSLAG FARE ARBEID IKKE p utstyr eller KABLER i TORDENV R INSTALLASJON ELEKTRISK AUTO SPENNINGSTILPASNING Dette produk...

Page 11: ...OQUE CAUSADO POR RAIO PERIGO N O TRABALHE no equipamento ou nos CABOS durante per odos suscet veis a QUEDAS DE RAIO INSTALA O EL TRICO AJUSTE AUTOM TICO DE VOLTAGEM Este produto ajustar se automaticam...

Page 12: ...ectar los cables LAN PELIGRO DE RAYOS PELIGRO NO REALICE NINGUN TIPO DE TRABAJO O CONEXION en los equipos o en LOS CABLES durante TORMENTAS ELECTRICAS INSTALACION ELECTRICO AUTO AJUSTE DE TENSION Este...

Page 13: ...las ur FARA F R BLIXTNEDSLAG FARA ARBETA EJ p utrustningen eller kablarna vid SKV DER INSTALLATION ELEKTRISKT AUTOMATISK SP NNINGSJUSTERING Denna produkt justeras automatiskt till alla sp nningar inom...

Page 14: ......

Page 15: ...p Installation 8 Wall Installation 9 Connectivity 9 PC to Switch Installation 10 Hub to Switch Installation 11 Hub to Switch Installation without uplink port 11 Switch to Switch Installation 12 Techni...

Page 16: ......

Page 17: ...r Panels The AT FS704 is designed for easy installation and high performance in an environment where traffic on the network and the numbers of users increase continuously it can be installed where spa...

Page 18: ...providing automatic and flexible solutions in your network connections Auto polarity detection for correction of incorrect polarity on the receive twisted pair at each port Data packet forwarding and...

Page 19: ...Figure 2 AT FS704 Front Panel defined Rear Panel The rear panel of the AT FS704 consists of an AC power connector as shown in Figure 3 Supported input voltages range from 100 240 V AC at 50 60 Hz Fig...

Page 20: ...s LEDs Color State Description 100M Green ON OFF Indicates a 100 Mbps device is connected to a respective port or the uplink port If a 10 Mbps device is connected to a respective port or the uplink po...

Page 21: ...5 Power Supply The AT FS704 can be used with AC power sources 100 240 V AC 50 60 Hz To power the unit ON plug one end of the power cord into the AC power connector of the unit and the other end into t...

Page 22: ......

Page 23: ...udes the following items One AT FS704 10 100 Fast Ethernet Switch One AC power cord for the U S Continental Europe and the U K only Warranty card This installation guide Four rubber feet with adhesive...

Page 24: ...d be within 1 82 m 6 ft of the device Cabling should be away from sources of electrical noise such as radios transmitters broadband amplifiers power lines and fluorescent fixtures Do not place objects...

Page 25: ...support holes located on the bottom of the switch Do not drill these holes too deep Insert the plastic anchors into the holes in the wall and secure them with gentle hammer taps Insert the screws pro...

Page 26: ...STP RJ45 straight cable The PC equipped with a RJ45 10 100 Mbps jack should be connected to any of the four ports 1X 4X See Figure 6 Figure 6 AT FS704 Switch Connected to a PC or Workstation 1 X 2X 3X...

Page 27: ...hub is not equipped with an uplink MDI port then connection can be made using either straight cable or crossover cable see Appendix A Technical Specifications for cable requirements Figure 8 demonstra...

Page 28: ...witch to Switch Connection Using the Straight or Crossover Cable Options Figure 9 demonstrates using straight or crossover cable When using straight cable connect the uplink MDI port of the switch Swi...

Page 29: ...orts 4 x 10 100 Mbps ports Media interface exchange MDI RJ45 shared with port 1X Agency Compliance Standard IEEE 802 3 10Base T Ethernet IEEE 802 3u 100Base TX Fast Ethernet ANSI IEEE Std 802 3 Auto N...

Page 30: ...overview of IEEE 802 3 and 802 3u cabling specifications for 10Base T 100Base TX and 100Base FX network configurations using twisted pair cable and fiber optics Table 2 IEEE 802 3 and 802 3u Cabling...

Page 31: ...uality cables If voice quality cables are used in a 100Base TX network system data movement may be slow collision prone or non existent In addition interface LEDs will usually indicate a valid link in...

Page 32: ......

Page 33: ..._____________ ______________________________________________________________________________ Brief summary of problem _______________________________________________________ __________________________...

Page 34: ......

Page 35: ..._____________________________________ ______________________________________________________________________ I would like the following more developed ________________________________ ________________...

Page 36: ......

Page 37: ...eece Turkey Israel 39 02 416047 39 02 419282 Japan 81 3 3443 5640 81 3 3443 2443 United Kingdom United Kingdom Denmark Norway Sweden Finland Iceland 44 1 235 442560 44 1 235 442490 Technical Bulletin...

Page 38: ......

Reviews: