Setting Up MBA in a Client Environment
Setting up a Multiple Boot Agent (MBA) in a client environment involves
the following procedures:
“Enabling the MBA Driver” on page 37
“Disabling the MBA Driver” on page 37
“Setting Up the BIOS” on page 37
Enabling the
MBA Driver
To enable MBA, perform the following procedure:
1. Power on the system with the card installed.
2. When prompted, enter CTRL-S to enter the NIC setup menu.
3. Set the pre-boot to PXE, which is the default setting.
Disabling the
MBA Driver
To disable MBA, perform the following procedure:
1. Power on the system with the card installed.
2. When prompted, enter CTRL-S to enter the NIC setup menu.
3. Set the pre-boot to None.
Note
If you set PXE to None on all the ports on the adapter, you will not be
able to access the CTRL-S prompt and NIC setup menu.
Note
The message prompting you to press CTRL+S is displayed only
once even if the computer has more than one AT-ANC10S Interface
Adapter. After you press CRTL+S, the Broadcom Comprehensive
Control Manager displays all the Broadcom devices that are
installed in the computer and that you can configure.
Setting Up the
BIOS
To boot from the network with the MBA, make the MBA enabled adapter
the first bootable device under the BIOS. This procedure depends on the
system BIOS implementation. Refer to the user manual for the system
BIOS implementation for instructions.
Summary of Contents for AT-ANC10S
Page 1: ...613 002022 Rev B AT ANC10S 2 10 Gigbit Network Interface Card Installation and User s Guide...
Page 6: ...6...
Page 10: ...List of Figures 10...
Page 12: ...List of Tables 12...
Page 16: ...Preface 16...
Page 29: ...AT ANC10S 2 Adapter Installation and User s Guide 29 Figure 5 Installing the Standard Bracket...
Page 58: ...Chapter 5 Installing the Windows Drivers 58...
Page 82: ...Chapter 7 Installing CIM and SNMP for Manageability 82...
Page 104: ...Chapter 9 Troubleshooting 104...
Page 116: ...Chapter 10 User Diagnostics 116...
Page 124: ...Appendix B Cleaning Fiber Optic Connectors 124...