Allied Telesis AT-A15/LX Quick Install Manual Download Page 12

Overview

6

For example, if you install an AT-A17 in slot B while leaving slot A empty, 
the switch will assign the port numbers 25 and 26 to the ports on the 
module. If you later install another AT-A17 in slot A, the switch will 
automatically reallocate port numbers 25 and 26 to the new modules in 
slot A and assign the port numbers 27 and 28 to the module in slot B. If 
the module in slot B had been a member of a VLAN, you would be 
required to reconfigure the VLAN to reflect the change to its port 
numbers.

3.

Remove the expansion module from the packing material. Make sure you 
observe ESD precautions.

4.

Slide the expansion module into the empty slot making sure the board is 
aligned properly with the card guides. Refer to Figure 7.

Figure 7  Installing an Expansion Module

5.

Secure the expansion module to the switch by tightening the captive 
screws.

6.

Apply power to the switch by re-attaching the power cord to the switch. 
Verify that the Power LED lights green.

7.

Remove the dust cover from the port(s) on the expansion module and 
connect the data cable(s).

A

B

AT-A17

100BASE-FX/SC

RX

TX

RX

TX

LINK

ACTIVITY

FULL DUP

HALF DUP

COL

LINK

ACTIVITY

FULL DUP

HALF DUP

COL

1

2

Board

Card Guide

Dust Covers

Summary of Contents for AT-A15/LX

Page 1: ...AT A15 SX AT A15 LX AT A16 AT A17 AT A18 AT A19 Expansion Modules Quick Install Guide PN 613 10814 00 Rev B...

Page 2: ...respective owners Allied Telesyn International Corp reserves the right to make changes in specifications and other information contained in this document without prior written notice The information p...

Page 3: ...ngua VIKTIG Tillegg A inneholder oversatt sikkerhetsinformasjon for installering av dette utstyret N r du ser pner du til Tillegg A for finne den oversatte sikkerhetsinformasjonen p nsket spr k IMPORT...

Page 4: ......

Page 5: ...stalling the Expansion Module 5 Changing the GBIC Module in the AT A15 SX or AT A15 LX Expansion Module 8 Appendix A Translated Safety Information 11 Appendix B AT A1x Series Expansion Module Quick In...

Page 6: ......

Page 7: ...ned to be installed into the two expansion slots on the front of each switch The expansion modules which can be installed in any combination offer you flexbility in building or expanding your network...

Page 8: ...Overview 2 Figure 3 AT A17 Expansion Module Figure 4 AT A18 Expansion Module Figure 5 AT A19 Expansion Module...

Page 9: ...sumes a fiber optic cable rating of 500 Mhz Km 62 5 125 micron multimode fiber 902 ft 275 m 3 3 Assumes a fiber optic cable rating of 200 Mhz Km AT A15 LX 1000Base LX SC 9 125 micron single mode fiber...

Page 10: ...pment or CABLES during periods of LIGHTNING ACTIVITY 8 Warning CAUTION POWER CORD IS USED AS A DISCONNECTION DEVICE TO DE ENERGISE EQUIPMENT disconnect the power cord 9 Caution Air vents must not be b...

Page 11: ...cord 9 2 Remove a blank faceplate from one of the expansion slots by unscrewing the faceplates two captive screws Refer to Figure 6 Do not remove the blank faceplate if you are not installing an expan...

Page 12: ...numbers 3 Remove the expansion module from the packing material Make sure you observe ESD precautions 4 Slide the expansion module into the empty slot making sure the board is aligned properly with th...

Page 13: ...AT A1x Series Expansion Module is now ready for use LED State Description Activity Link Solid Green Indicates a 100 Mbps link Flashing Green Indicates 100 Mbps activity Solid Amber Indicates a 10 Mbps...

Page 14: ...the expansion module has been installed in the switch If you have not installed the AT A15 SX or LX module in the switch refer to Installing the Expansion Module on page 5 To change the GBIC module pe...

Page 15: ...n Slot 4 Remove the dust cover and attach the fiber cables It is important to leave the dust cover in place if you are not attaching the cables at this time Dust in the ports will degrade transmission...

Page 16: ......

Page 17: ...es instructions de s curit figurant dans ce guide T RKE T m liite sis lt t ss oppaassa esiintyv t turvaohjeet usealla kielell IMPORTANTE questa appendice contiene traduzioni in pi lingue degli avvisi...

Page 18: ...must have free access to the room ambient air for cooling U S Federal Communications Commission Note This equipment has been tested and found to comply with the limits for a Class A digital device pu...

Page 19: ...GEFAHR Keine Arbeiten am Ger t oder an den Kabeln w hrend eines Gewitters ausf hren 9 VORSICHT DAS NETZKABEL DIENT ZUM TRENNEN DER STROMVERSORGUNG ZUR TRENNUNG VOM NETZ KABEL AUS DER STECKDOSE ZIEHEN...

Page 20: ...de eisen 1 RFI Emissie EN55022 Klasse A 2 WAARSCHUWING Binnenshuis kan dit product radiostoring veroorzaken in welk geval de gebruiker verplicht kan worden om gepaste maatregelen te nemen 3 Immuniteit...

Page 21: ...ION DU MAT RIEL d brancher le cordon 10 ATTENTION Ne pas bloquer les fentes d a ration ceci emp cherait l air ambiant de circuler librement pour le refroidissement 11 TEMP RATURE DE FONCTIONNEMENT Ce...

Page 22: ...caso potrebbe richiedersi all utente di prendere gli adeguati provvedimenti 3 Immunit EN50082 1 1997 4 Sicurezza elettrica TUV EN60950 UL1950 CSA 950 5 Laser EN60825 6 AVVERTENZA Prodotto laser di Cla...

Page 23: ...FORSIKTIG Lufteventilene m ikke blokkeres og m ha fri tilgang til luft med romtemperatur for avkj ling 11 DRIFTSTEMPERATUR Dette produktet er konstruert for bruk i maksimum romtemperatur p 40 grader...

Page 24: ...ncias en cuyo caso puede requerirse del usuario que tome las medidas que sean convenientes al respecto 3 Inmunidad EN50082 1 1997 4 Seguridad el ctrica TUV EN60950 UL1950 CSA 950 5 Laser EN60825 6 ADV...

Page 25: ...rprodukt av klass 1 7 VARNING Laserstr lning n r enheten r ppen 8 FARA F R BLIXTNEDSLAG FARA ARBETA EJ p utrustningen eller kablarna vid SKV DER 9 VARNING N TKABELN ANV NDS SOM STR MBRYTARE F R ATT KO...

Page 26: ......

Page 27: ..._________________________ ______________________________________________________________________ I would like the following more developed ________________________________ ____________________________...

Page 28: ......

Page 29: ...____________________________________________ Brief summary of problem ______________________________________________________ ___________________________________________________________________________...

Page 30: ......

Page 31: ...y Italy Spain Portugal Greece Turkey Israel 39 02 416047 39 02 419282 Japan 81 3 3443 5640 81 3 3443 2443 United Kingdom United Kingdom Denmark Norway Sweden Finland Iceland 44 1 235 442560 44 1 235 4...

Page 32: ......

Reviews: