background image

AT-9800 Series Switch 
Hardware Reference 

AT-9812T V2
AT-9816GB V2

AT-RPS9000
AT-PWR9000

Summary of Contents for AT-9812T V2

Page 1: ...AT 9800 Series Switch Hardware Reference AT 9812TV2 AT 9816GBV2 AT RPS9000 AT PWR9000...

Page 2: ...notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever inclu...

Page 3: ...232 Terminal and Modem Cables 14 Cables for RJ 45 Ethernet LAN Interfaces 15 Cable Guidelines 16 Redundant Power Supply RPS 17 AT RPS9000 Specifications 18 AT TFTP Server 19 Using Windows Terminal an...

Page 4: ...rdware expansion options such as CompactFlash CAM and DIMM the AT 9800 Series is a versatile and powerful switching solution for rapidly evolving networks Dimensions Height 66mm plus 5 5 mm if the rub...

Page 5: ...ble expansion of flash up to 512MBytes 512kBytes of Non volatile SRAM NVRAM Battery backed real time clock RTC 32 66MHz PCI bus Silicon ID chip storing serial number board ID and MAC address Asynchron...

Page 6: ...A D C L A GBIC L A GBIC ASYN0 1000BASE X GBIC 10BASE T 100BASE TX 1000BASE T ACT 1000M L A ACT 10 100M COL FULL DUP HALF DUP D C FAULT ACT LINK FULL DUP L A ACT LINK HALF DUP DISABLED ENABLED GBIC GB...

Page 7: ...re sensor located immediately adjacent to the switch chip has exceeded the recommended threshold of 60 degrees Celsius RPS Redundant Power Supply Green An RPS is connected to the switch and is receivi...

Page 8: ...ion GBIC L A Link activity Green A 1000 Mbps link is open The link is operating in full duplex mode Flashing green 1000 Mbps full duplex activity is occurring Amber A 1000 Mbps link is open The link i...

Page 9: ...from a remote location via a modem connection You can also use ASYN0 to establish a network connection from a remote site using SLIP and a modem ASYN0 has a DCE female socket This allows the use of a...

Page 10: ...portant RX and TX terminal locations on SC fibre GBIC ports are the reverse of RX and TX terminal locations on fixed SC fibre ports When looking at an SC fibre GBIC from the front the RX terminal is o...

Page 11: ...mpactFlash card AT CF128A 00 128MB CompactFlash card For the latest list of approved CompactFlash cards contact your authorised Allied Telesis distributor or reseller or visit www alliedtelesis com su...

Page 12: ...cflash test command The test software will read the file allocation table and display a list of free sectors Sectors can be tested as single sectors or as a range The test will consist of a write read...

Page 13: ...L2 L3 tables LineCAM can be ordered as a pre installed item when purchasing a switch or can be purchased separately For more information contact your authorised Allied Telesis distributor or reseller...

Page 14: ...32 DB9 male to male modem cable Figures in this section show pin wiring diagrams to connect a standard VT100 compatible terminal or modem to ASYN0 RS 232 DB9 male to female terminal cable Notes 1 Outp...

Page 15: ...r cables with RJ 45 connectors Pin assignments Each pair of twisted pair cables is identified by related colours For example one wire might be red and the related wire would be red and white stripe An...

Page 16: ...RJ 45 four pair cross over cable Cable Guidelines The following table lists port connector and cable combinations for AT 9800 Series switches and GBICs 1 Refer to the IEEE 802 3 standards for further...

Page 17: ...pport up to four switches The AT RPS9000 chassis has two AC power inlets Each inlet supplies two bays and therefore two AT PWR9000 units and two switches Rear panel of the AT RPS9000 The pin layout an...

Page 18: ...ction fault located on AT 9800 Series switches RPS is supplying power to switch located on AT 9800 Series switches For LED descriptions see Switch LEDs on page 7 Controls Individual power switch for e...

Page 19: ...field specifies the directory that AT TFTP Server will read from or write to for file requests that do not include a directory specification To prevent unauthorised access to private directories enter...

Page 20: ...allations HyperTerminal is available from the Communications submenu The key to successful use of terminal emulation software with the switch is to configure the software and switch with matching comm...

Page 21: ...EV F 3 In the Connect using field on the Connect To dialog box select the COM port on the PC used to connect to the switch and click the OK button 4 In the COMn Properties dialog box set port paramete...

Page 22: ...Settings tab and set the Properties dialog box as follows 6 Click ASCII Setup to display the ASCII Setup dialog box and ensure the following options are not selected Echo typed characters locally Appe...

Page 23: ...YN0 A terminal cable suitable for use with ASYN0 is supplied with each switch Using the supplied terminal cable or a cable you have made by following the instructions in Cables on page 14 connect your...

Page 24: ...elp topic You can also type a question mark at the end of a partially completed command to see a list of valid options Startup Procedure When the switch starts up following either a power cycle or an...

Page 25: ...perate FAIL An error message that a fatal error condition has caused the system to halt in an unrecoverable fashion Message Description INFO Self tests beginning Code loader tests are about to begin I...

Page 26: ...displayed amount of memory was found This amount is less than the minimum required to run the switch software INFO Self tests complete The startup tests have finished INFO Downloading switch software...

Page 27: ...ested Test results are displayed using the command show test The following figure shows typical output from the show test command A more detailed output with frame counts can be displayed using the co...

Page 28: ...P1 0 42029694 Duration Frame Counters Interface State Type minutes Tx RxTotal RxGood RxBad port1 testing TP 1 000298842 000298841 000298841 000000000 port2 no test port3 no test port4 testing TP 1 00...

Page 29: ...edWare Operating System Software Reference for more information about obtaining the latest software release 7 If the switch is malfunctioning reboot it by pressing the recessed RESET button or enterin...

Page 30: ...Fault LED is on This can indicate there is a problem with the switch or PSU the switch or management software is malfunctioning a hardware fault is preventing switch startup Perform the following step...

Page 31: ...use danger of injury from electric shock damage to the switch and invalidation of the product warranty To install LineCAM in an AT 9800 series switch 1 Avoid injury by working in a safe environment Th...

Page 32: ...d with the holes on the CAM and the CAM s chamfers should be pointing to the switch s PSU 8 Insert the CAM Warning Forcing a misaligned CAM will damage the CAM s connector and CAM slot Press the CAM f...

Page 33: ...e CAM alignment and insertion steps Use the show switch command again and if the display is still not correct contact your authorised Allied Telesis distributor or reseller Important If any CAM test f...

Page 34: ...ore removing the switch s lid the power cord and if connected RPS power cord should be disconnected to reduce risk of electrical shock 4 Remove all interface cables 5 Remove the switch s lid The switc...

Page 35: ...figure Insert the DIMM into the DIMM slot sliding it along the two DIMM guides until the retaining latches automatically click into place The latches should hold the DIMM firmly in place Testing DIMM...

Page 36: ...the serial numbers of both the base card on the switch and the DIMM The switch s serial numbers and revision details can be read using the show system command It s a good idea to record this informat...

Page 37: ...0 Using a terminal cable connect a terminal to the RS 232 port ASYN0 on the switch See Cables on page 14 for more information on terminal cables Set the terminal communication parameters to the follow...

Page 38: ...T 9800 Series Statutory and Safety Information booklet which includes important safety information and statutory declarations for AT 9800 Series switches The AT RPS9000 Statutory and Safety Informatio...

Page 39: ...ocument toolbar buttons such as the Next Page button keyboard shortcuts such as arrow keys commands from the Document menu mouse wheel To go to a specific section or topic click a bookmark thumbnail o...

Reviews: