3.

Log in

After the switch has booted, the log-in prompt appears. If the log-in 
prompt doesn’t appear, press [Enter] two or three times.

When the switch boots for the first time, it automatically creates an account 
with manager privileges. The account has the log in name “manager” and 
the password is “friend”.

At the log-in prompt, enter the log-in name and password.

Login: 

manager

Password: 

friend

The switch’s command prompt appears and you can now configure the 
switch using the command line interface.

Change the password as soon as possible. Leaving the manager account with 
the default password is a serious security risk. Make sure you remember the 
new password as there is no way to retrieve it if it is lost.

Use the following command to change the account password:

set password

4.

Load help files

To display a list of help topics, enter:

help

To display help on a specific topic, enter:

help 

topic

Alternatively, type a question mark (?) at the end of a partially completed 
command to see a list of valid options.

See the 

AT-8700XL Series Software Reference

 for more information on 

configuring the switch.

Using the GUI to configure a router:

This section describes how to establish a connection to the router through the 
GUI, so you can configure the router before installing it in your LAN. For more 
information about the GUI, see the Using the Graphical User Interface chapter 
of the 

AT-8700XL Series Software Reference

.

1.

Select a PC to browse to the 

router

 from

You can browse to the router from any PC that is running a supported 
operating system with a supported browser installed. JavaScript must be 
enabled. If you are using a toolbar or plug-in on your browser to block 
pop-ups, disable it while using the GUI. The GUI displays detailed 
configuration options and information in pop-up windows.

You need to know the PC’s subnet.

Summary of Contents for AT-8724XL

Page 1: ...AT 8700XL Series Switch Quick Install Guide AT 8724XL AT 8748XL ...

Page 2: ...ke changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesyn be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information containe...

Page 3: ... only One serial cable for connecting the switch to a terminal or PC One 19 inch rack mount kit One AT 8700XL Series Quick Install Guide One Safety and Statutory Information booklet One AT 8700XL Series Documentation and Tools CD ROM which includes the complete AT 8700XL Series Document Set and utilities One warranty card AT 8700XL Series Printed Acrobat PDF Website Documentation Roadmap AT 8700XL...

Page 4: ...ng maximum cable length limitations See the AT 8700XL Series Hardware Reference for cable length specifications Installing the Switch All AC and DC versions of this equipment must be earthed Follow these steps to install the switch 1 Before installing the switch read the safety information For safety information see the Safety and Statutory Information booklet A copy of this booklet is supplied wi...

Page 5: ... operate or damage to the switch may result 8 Apply AC power to the switch for AC models Plug the power cord into the AC power connector on the switch s rear panel The Fault LED should flash for approximately 10 seconds as the switch runs internal tests If the LED continues to flash or remains lit refer to the AT 8700XL Series Hardware Reference for troubleshooting information Figure 1 AT 8724XL f...

Page 6: ... negative grounded Circuit protection Use a 10 Amp circuit breaker To connect the DC supply a Ensure the supply cable is not live b Strip the supply cable wires to expose 8mm 0 31 in of bare conductor c At the switch connect the ground wire to the ground terminal terminals can be identified by the diagram on the switch s rear panel see Figure 2 Tighten the terminal to between 0 6 0 8 Nm 0 041 0 05...

Page 7: ...uthorised Allied Telesyn distributer or reseller for more information 12 Connect the data cables Make sure each cable connection is secure The switch will now perform basic Layer 2 switching functions Configuring the Switch Some configuration is necessary if you wish to enable the switch s advanced switching capabilities The switch can be configured via the Command Line Interface CLI or Graphical ...

Page 8: ...p files To display a list of help topics enter help To display help on a specific topic enter help topic Alternatively type a question mark at the end of a partially completed command to see a list of valid options See the AT 8700XL Series Software Reference for more information on configuring the switch Using the GUI to configure a router This section describes how to establish a connection to th...

Page 9: ...able IP enable ip 5 Assign the vlan1 interface an IP address in the same subnet as the PC add ip interface vlan1 ip ipaddress mask mask 6 Save the configuration and set the router to use it on bootup create config your name cfg set config your name cfg 7 On the PC s web browser bypass the HTTP proxy server if necessary 8 Point your web browser at vlan1 s IP address 9 At the login prompt enter the ...

Page 10: ...he hardware features of AT 8700XL Series switches This Quick Install guide The AT 8700XL Series Software Reference which provides detailed information on configuring the switch and its software The Uplink Module Quick Install Guide which outlines the procedure for installing an Uplink Module and the Uplink Module Hardware Reference which provides detailed information on Uplink Modules AT TFTP Serv...

Reviews: