![Allied Telesis AT-6101GP Installation Manual Download Page 17](http://html1.mh-extra.com/html/allied-telesis/at-6101gp/at-6101gp_installation-manual_2902108017.webp)
AT-6101 PoE Injector Installation Guide
13
Cable
Requirements
The cable requirements of the ports are given in Table 1.
Port Pinouts
Refer to Table 7 on page 28 for the port pinouts of the
10/100Base-TX/1000Base-T twisted pair ports.
Table 1. Twisted Pair Cable for the 10/100/1000Base-T Ports
Cable Type
10Mbps
100Mbps
1000Mbps
Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Yes
Yes
No
Standard TIA/EIA 568-A-
compliant Category 5 or TIA/
EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Yes
Yes
Yes
Standard TIA/EIA 568-B-
compliant Category 6 or 6a
shielded cabling.
Yes
Yes
Yes