AT-29xx Series Gigabit Ethernet Adapters Installation Guide
29
Connecting the Network Cables
All the fiber Gigabit Ethernet network adapters have two fiber optic
connectors for attaching the system to a compatible link partner, or an
IEEE 802.3z compliant gigabit switch. After connecting the system to the
network and power is supplied, the adapter performs auto-negotiation and
attempts to establish the connection at 1000 Mbps full-duplex only.
To connect a network cable to the adapter, perform the following
procedure:
1. Prepare a fiber optic cable according to the specifications in Table 4.
Warning
The fiber optic ports contain a Class 1 laser device. When the ports
are disconnected, always cover them with the provided plug.
Exposed ports may cause skin or eye damage
.
2. Connect one end of the cable to the adapter.
3. Connect the other end of the cable to the appropriate Ethernet network
port or fiber optic port.
Note
After the cable is properly connected at both ends, the adapter port
LEDs should be functional. See “LEDs” on page 16 for a description
of LED operation for each adapter model. For driver installation and
configuration instructions, refer to the software configuration for a
specific driver.
Table 4. 1000BASE-SX Fiber Optic Cable Specifications
Port Type
Connector
Media
Maximum
Distance
1000BASE-SX
Fiber Optic
50 µm
multimode
550 meters
(1,804 feet)
1000BASE-SX
Fiber Optic
62.5 µm
multimode
275 meters
(853 feet)