Hardware Reference
55
C613-03031-01 REV E
Figure 24: Front and rear panels of the AT-RPS 740.
DC supply cables
Two DC supply cables are packed with each AT-RPS 740. If making your own
cable, use a cable that conforms to UL2464, and has at least twenty-three
24AWG cores. The cables will need a DB25 male connector on both ends and
should be wired in a straight-through configuration. Pin outs for the
connectors are listed in Table 24 on page 56.
Figure 25: DB25 male pinout on the AT-RPS 740
Front panel
Rear panel
AC power
supply switches
AC power
supply inlets
LEDs
DC power outlets
(DB25s)
RPS DC OUTPUT 1
RPS STATUS
RPS DC OUTPUT 2
AC POWER 1
AC POWER 2
AC Power
On
RPS Fan
Fault
Main PSU
Fault
RPS PSU
Fault
Main Fan
Fault
1
2
ROUTER STATUS
AC Power
100-240 VAC
50-60Hz
1.5A
AC Power
100-240 VAC
50-60Hz
1.5A
5V/6.5A
12V/1.0A
-12V/0.2A
5V/6.5A
12V/1.0A
-12V/0.2A
A740rpsp
Pin 14
Pin 25
Pin 1
Pin13