We start from a Tornado WebJet 128 which has the following settings:
*
protocol 6 is for voice (S111 is 1).
*
Protocol 11 is for PAD (S111 is 7).
*
S112=35 (maximum information and automatic PAD VC).
AT&O6*D/11
Select protocol 6, dial ISDN number 11.
OK:6,0,6
Direct response that call number 6 on ISDN access number 0 is being established
using protocol 6.
PROGRESS:6,0,0,6,1
Message for call no. 6 using protocol 6, channel B1, communication with analog
network.
ALERT:6,0,6,1
The device called is ringing: ALERT message.
CONNECTED:6,,0,6,1
First call (6) has been established, channel B1 has been selected.
CLEARED:6,10
Call (6) has been broken off by normal cause (10).
AT*D/69855044*5/"Hello"
While the first connection is being established, a second command follows to dial
ISDN number 69855044, subaddress 5 and User Information "Hello".
Note that it isn’t necessary to give the &O6 command as this protocol is already
active.
OK:6,0,6
Direct response that call number 6 on ISDN access number 0 is being established
using protocol 6.
CONNECTED:6,”Welkom”,0,1,2
Second call (6) has been established. Channel B2 has been selected. The recipient
responded with "Welcome"
AT*H0/6
Break off call no. 6
Hex
Decimal
Description
65
101
message not compatible with call state
66
102
recovery on timer expired
6F
111
protocol error, unspecified
7F
127
interworking, unspecified
91
145
no signalling data link establishment
A2
162
no line activation
FF
255
call clearing, unspecified