Command reference
R&S
®
ZND
709
User Manual 1173.9557.02 ─ 61
CALCulate<Chn>:MARKer<Mk>:TARGet
<TargetSearchVal>
Defines the target value for the target search of marker no.
<Mk>
, which can be activa-
ted using
CALCulate<Chn>:MARKer<Mk>:FUNCtion:EXECute
TARGet
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
<Mk>
Marker number.
Parameters:
<TargetSearchVal>
Target search value of marker no.
<Mk>
.
The value range and reset value depend on the selected target
format (see
CALCulate<Chn>:MARKer<Mk>:SEARch:
Example:
CALC:MARK ON
Create marker no. 1 and display it in the center of the sweep
range.
:CALC:MARK:TARG -10; FUNC:EXEC TARG
Define a target search value of -10 dB and start the target
search.
CALC:MARK:X?
Query the stimulus value corresponding to the target search
result.
Manual operation:
CALCulate<Chn>:MARKer<Mk>:THReshold
<Value>
Defines a marker-specific threshold value for (single) peak searches.
CALCulate<Chn>:MARKer<Mk>:THReshold:STATe
to activate it.
Suffix:
<Chn>
.
Channel number used to identify the active trace
<Mk>
Marker number
Parameters:
<Value>
Threshold value
The unit is derived from the active trace format and cannot be
modified. Changing the trace format resets the threshold to a
format-specific default value.
Manual operation:
CALCulate<Chn>:MARKer<Mk>:THReshold:STATe
<Active>
Activates or deactivates the marker-specific threshold for (single) peak searches.
CALCulate<Chn>:MARKer<Mk>:THReshold
to set the threshold value.
Suffix:
<Chn>
.
Channel number used to identify the active trace
SCPI command reference
www.allice.de