Command reference
R&S
®
ZND
1099
User Manual 1173.9557.02 ─ 61
Parameters:
<EnableTriggOut>
Turn trigger output on (ON) or off (OFF, no signal).
*RST:
OFF
Example:
TRIGger:CHANnel:AUXiliary:ENABle ON
Turn on the trigger output for channel no. 1 (channel suffix omit-
ted).
TRIGger:CHANnel:AUXiliary:DURation 10 us
Change the width of the output trigger pulses.
TRIGger:CHANnel:AUXiliary:POSition BEFore
Send the output trigger pulses before data acquisition starts.
TRIGger:CHANnel:AUXiliary:INTerval SWEep
Send one output trigger pulse per sweep.
TRIGger:CHANnel:AUXiliary:OPOLarity POSitive
Select positive polarity for the output trigger pulses.
TRIGger:CHANnel<Ch>:AUXiliary:INTerval
<Type>
Specifies whether the trigger output pulses are sent once every partial measurement
(POINt) or once every sweep.
Suffix:
<Ch>
.
Channel number
Parameters:
<Type>
POINt | SWEep
*RST:
SWEep
Example:
TRIGger:CHANnel<Ch>:AUXiliary[:ENABle]
TRIGger:CHANnel<Ch>:AUXiliary:OPOLarity
<Type>
Selects the polarity of the output trigger pulses; see
.
Suffix:
<Ch>
.
Channel number
Parameters:
<Type>
POSitive | NEGative
*RST:
NEGative
Example:
TRIGger:CHANnel<Ch>:AUXiliary[:ENABle]
TRIGger:CHANnel<Ch>:AUXiliary:POSition
<Type>
Specifies whether the trigger output pulse is sent before or after the selected sweep
interval (see
TRIGger:CHANnel<Ch>:AUXiliary:INTerval
SCPI command reference
www.allice.de
Allice Messtechnik GmbH