Command reference
R&S
®
ZND
1048
User Manual 1173.9557.02 ─ 61
STATus:QUEStionable:INTegrity:HARDware:PTRansition
<BitPattern>
STATus:QUEStionable:LIMit<Lev>:PTRansition
<BitPattern>
Configures the positive transition filters of the
QUEStionable...
status registers. If a
bit is set, a 0 to 1 transition in the corresponding bit of the associated condition register
causes a 1 to be written in the associated bit of the corresponding event register.
Chapter 6.5.5, "Reset values of the status reporting system"
Suffix:
<Lev>
.
Selects one of the two
QUEStionable:LIMit
registers; see
"STATus:QUEStionable:LIMit<1|2>"
Parameters:
<BitPattern>
Range:
0 to 65535 (decimal representation)
*RST:
n/a
Example:
STAT:QUES:LIM2:PTR 6
Set bits no. 1 and 2 of the
QUEStionable:LIMit2:PTRansition
register
STATus:QUEue[:NEXT]?
Queries and at the same time deletes the oldest entry in the error queue. Operation is
identical to that of
The entry consists of an error number and a short description of the error. Positive
error numbers are instrument-dependent. Negative error numbers are reserved by the
SCPI standard; see section
Chapter 9, "Error messages and troubleshooting"
Example:
STAT:QUE?
Query the oldest entry in the error queue.
0,"No error"
is
returned if the error queue is empty.
Usage:
Query only
7.3.17
SYSTem commands
The
SYSTem...
commands provide functions that are not related to instrument perfor-
mance, such as functions for general housekeeping and functions related to global
configurations.
7.3.17.1
SYSTem:COMMunicate...
The
SYSTem:COMMunicate...
commands provide remote control settings and con-
figure remote (external) devices controlled by the R&S
ZND.
SYSTem:COMMunicate:AKAL:CONNection
....................................................................1049
SYSTem:COMMunicate:AKAL:MMEMory[:STATe]
........................................................... 1050
.....................................................................................1050
SYSTem:COMMunicate:GPIB[:SELF]:ADDRess
............................................................. 1051
SCPI command reference
www.allice.de
Allice Messtechnik GmbH