Rear View of Wall
CAR26N_SVG
7
6
5
4
3
2
1
1.
15 Amp – Three-Phase Circuit Breaker
2.
0.75 in. [19 mm] Water Outlet
3.
0.75 in. [19 mm] min. Cold Water Supply Line
4.
0.75 in. [19 mm] min. Hot Water Supply Line
5.
60 in. [152 mm] Required
6.
2 in. [51 mm] min. Waste Line Tee
7.
4 in. [102 mm] min. Waste Line
Figure 6
Drain Line Sizing / Minimum Drain ID
Number of Machines
Drain Line Size
1
2 in. [51 mm]
2
3 in. [76 mm]
3
4 in. [102 mm]
4
4 in. [102 mm]
5
4 in. [102 mm]
6
4 in. [102 mm]
7 – 10
6 in. [152 mm]
Table 9
Water Connection
Connections should be supplied by a hot and a cold water line of
at least the sizes shown in the Water Supply Line Sizing table.
Refer to
Table 10
.
Water Supply Line Sizing
Number of Machines
Drain Line Size
1
0.75 in. [19 mm]
2
1 in. [25 mm]
3
1.25 in. [32 mm]
4
1.5 in. [38 mm]
5
1.5 in. [38 mm]
Table 10
continues...
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
18
F8221501ENR4
Summary of Contents for UM202 series