Control Always in Audit Display Mode (Vend Models)
Coin models: Is coin
vault switch being
pressed in?
(D)
Is J19 plug fully
inserted and in good
condition?
Yes
Ensure that your coin
box is pressing coin
vault switch. If coin
box is too short,
either install longer
box, or manually
depress switch.
No
(C)
Is there 5VDC when
measuring between
H11-1 & H11-3 on AP2?
Yes
Repair/ replace J19
plug as necessary.
No
(C)
If there is less than
1VDC between H11-1 &
H11-3 on AP2 and you
still can’t exit
Audit Display Mode
replace AP2 Control
Logic Board.
No
Coin vault audit
switch circuit is
open, check switch
and wiring.
Yes
Troubleshooting
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
118
Part No. F8677701EN
Summary of Contents for SCA030FN
Page 2: ......