AA –HP410-2011-02 Alliance Cycle-Heating Household Heat Pump Water Heater Technical Manual
9
Outdoor air flow
m3/h
2000
2000
3200
Outdoor noise level
dB(A)
49
55
55
Outdoor
unit
Dimension
(W*H*D)
mm
790×736×260
790×736×260
840×940×324
Packing
(W*H*D)
mm
905×807×355
905×807×355
965×1009×395
Net/Gross
weight
kg
54/57
62/66
81/86.5
Refrigerant type/Quantity
kg
R410A/0.95
R410A/1.2
R410A/1.3
Design pressure
MPa
4.4/2.2
4.4/2.2
4.4/2.2
Refrigerant
piping
Liquid/ Gas
side
mm
/
Ф
9.52
/
Ф
9.52
Ф
7.94/
Ф
12.7
Max. pipe
length
(
water
)
m
5
5
5
Max. difference in level of
the unit and tank
m
3
3
3
Ambient temp
℃
-7
℃
-43
℃
-7
℃
-43
℃
-7
℃
-43
℃
water pipe
Diameter,
water inlet
pipe
mm
DN20
DN20
DN20
Diameter,
water outlet
pipe
mm
DN20
DN20
DN20
Diameter,
water
circulating
pipe
mm
DN20
DN20
DN20
Wire Controller
KJR-26B/GWE
KJR-26B/GWE
KJR-26B/GWE
Hot Water Yield
m
3
/h
0.516
0.86m
1.12
Water outlet temp.
℃
40
℃~
60
℃
40
℃~
60
℃
40
℃~
60
℃
Remark:
1. The test conditions: outdoor temp.7.0/6.0
℃
(DB/WB), inlet water temp. 30
℃
, outlet water temp. 35
℃
.
2. The operation range:-7
℃
-43
℃
.
3. Specifications may change due to product improvements. Please refer to the nameplate.