60549
79
Section 8 Service Procedures Unique to Electronic Control Model Dryers
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
NOTE:
1. This test routine will only light in the LED’s pertaining to the hardware model selected.
2. When the last step in the table is finished, the routine sequence will repeat.
3. East output is on for two seconds.
LED
Display
Illuminated
LED
Motor
Relay
Heat
Relay
Signal
Volume
99
None (All Off)
On
Off
Off
88
Wrinkle Free Status
Off
Off
Off
77
Cool
Down
Off Off Off
66
Drying
Off Off Off
55
Clean
Filter
Off Off Off
44
Memory
Off Off Off
33
Damp
Off Off Off
22
Normal
Off Off Off
11
Extra
Dry
Off Off Off
00
Very
Dry
Off Off Off
99
None (All Off)
Off
Off
Softest
88
None (All Off)
Off
Off
Medium
77
None (All Off)
Off
Off
Loudest
77
Signal
Off Off Off
55
Wrinkle-Free
Select
Off Off Off
44
No
Heat
Off Off Off
33
Knits
Off Off Off
22
Delicates
Off Off Off
11
Perm
Press
Off Off Off
00
Regular
Off Off Off
99
None (All Off)
Off
On
Off
88
None (All Off)
On
On
Off
Figure 60