![Alliance Products DALPH1022 Operation Manual Download Page 13](http://html.mh-extra.com/html/alliance-products/dalph1022/dalph1022_operation-manual_2901661013.webp)
13
PREVENTIVE MAINTENANCE
Casters
1.
Check casters for freedom of movement and proper brake operation.
2.
Maintain casters free of debris. (mop strings, paper, plastic, hair nets, etc…)
3.
Clean or replace as required.
Cord and Plug
1.
Inspect plug blades for distortion and replace if any blades are missing, bent
or broken.
2.
Inspect cord wiring for integrity at termination points by having qualified
service person remove the back panel from the cabinet. Make sure the cord
sheathing extends into the cabinet interior. If wires are showing on the
outside of the cabinet, remove the unit from use and have repairs made before
turning on power to the unit.
Dispensing Mechanism
1.
Periodically check springs for proper dispensing by filling each cavity with
pellets / plates and checking to see that it indexes as they are removed. If
pellets / plates do not index properly, and unit is not overloaded, adjust or
replace springs.
Summary of Contents for DALPH1022
Page 10: ...10 DALPH1022 Exploded View Drawing ...
Page 11: ...11 Dispenser Assembly Exploded View Drawing ...
Page 12: ...12 Wiring Diagram ...