37987
69
Section 6 Adjustments
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
50. OUT-OF-BALANCE SWITCH
a. Remove two screws from bottom edge of front
panel. Refer to Figure 25.
b. Pull bottom of panel away from washer until
hold-down clips (located on top flange of
panel) disengage from slots in cabinet top.
Refer to Figure 25.
c. Hinge or remove cabinet top. Refer to
d. Check for bent actuator arm or lever. Refer to
IMPORTANT: If switch lever repeatedly trips the
out-of-balance switch, check centering of agitator
within the loading door opening. If tub module is
not centered within opening, centering spring(s)
may have been overstretched. Replace necessary
spring(s) and recheck centering. Refer to Figure 51.
Figure 50
Out-of-Balance
S
witch A
ss
embly
W215
S
E1A
Actuator
Arm
Lever
Figure 51
Centering
Spring
W308SE1B
Holes