2 Water Connection Models
1
2
CFD1213N
1.
Refer to
.
2.
Refer to
.
Figure 21
3 Water Connection Models
2
1
3
CFD1214N
1.
Refer to
.
2.
Refer to
.
3.
Refer to
.
Figure 22
Water
type
Water connection
1
2
3
Table 14
continues...
Water
type
Water connection
Cold and Hot
Cold
Hot
N/A
Cold soft,
Cold hard and
Hot
Cold soft
Hot
Cold hard
Table 14
WARNING
If the water pressure is below the minimum value,
the wash result can not be guaranteed for a selected
program.
W914
The maximum water inlet temperature for vended models is
151°F [66°C]and the maximum water inlet temperature for on-
premises models is 194°F [90°C] (models without WRAS appro-
val) or 140°F [60°C] (WRAS approved models).
Connections should be supplied by a hot and a cold water line of
at least the sizes shown in Water Supply Line Sizing . Installation
of additional machines will require proportionately larger water
lines.
Connections should be supplied by a hot and a cold water line per
national and local codes and in accordance with IEC 61770.
To connect water service to a machine with hoses, use the follow-
ing procedure:
1. Before installing hoses, flush the building’s water system at
the machine connection valves for at least two (2) minutes.
2. Check filters in the machine’s inlet hoses for proper fit and
cleanliness before connecting.
3. Hang hoses in a large loop; do not allow them to kink.
If additional hose lengths are needed or using hoses other than
those supplied by manufacturer, flexible hoses with screen filters
are required.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
39
Part No. D1598ENR10