background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

4

70444801

Introduction

Model Identification

Information in this manual is applicable to these 
models:

Includes models with the following control suffixes:

Nameplate Location

The nameplate is located on the back of the machine 
and is programmed in the UniLinc Control. To access 
Machine ID Menu through the control:

1. Press and hold

, then

, then

 

keypads at the same time.

2. Press the

keypad until Diagnostic is 

highlighted.

3. Press the

keypad.

4. Press the

keypad until Machine ID is 

highlighted.

5. Press the

keypad.

Always provide the machine’s serial number and 
model number when ordering parts or when seeking 
technical assistance. Refer to 

Figure 1

.

Figure 1 

Gas

Steam/Thermal Oil

Electric

25 Pound

UA025L
UA025N

UT025L
UT025N

UU025L
UU025N

UT025S

UU025S

UT025E

UU025E

30 Pound

UA030L
UA030N

UT030L
UT030N

UU030L
UU030N

UT030S

UU030S

UT030E

UU030E

35 Pound

UA035L
UA035N

UT035L
UT035N

UU035L
UU035N

UT035S

UU035S

UT035E

UU035E

50 Pound

UA050L
UA050N

UT050L
UT050N

UU050L
UU050N

UT050S
UT050T

UU050S
UU050T

UT050E

UU050E

55 Pound

UA055L
UA055N

UT055L
UT055N

UU055L
UU055N

Not Applicable

UT055E

UU055E

75 Pound

UA075L
UA075N
UT075L

UT075N
UTF75L
UTF75N

UU075L
UU075N

UT075S
UT075T

UU075S
UU075T

UB075E
UT075E

UU075E

120 Pound

UA120L
UA120N

UT120L
UT120N

UU120L
UU120N

UT120S
UT120T

UU120S
UU120T

Not Applicable

170 Pound

UA170L
UA170N

UT170L
UT170N

UU170L
UU170N

UT170S
UT170T

UU170S
UU170T

Not Applicable

UO – UniLinc OPL

RU – reversing UniLinc OPL

TMB1332R

Machine ID

Model:

UT030NUOG2K0W01

Serial #:

1107002759

Install Date:

07/01/2011

Machine Type:

30

Control SN:

11410113

Front End SW:

1

Display SW:

1

Node Number:

250

Summary of Contents for TMB1276C

Page 1: ...Tumble Dryer UniLinc Control Refer to Page 4 for Model Identification TMB1276C TMB1276C Part No 70444801R3 July 2011 Keep These Instructions for Future Reference If this machine changes ownership this...

Page 2: ......

Page 3: ...niLinc Identification 7 Operational Keypad 7 Operation Modes 8 General Modes of Operation 8 Power up Mode 8 Idle Mode 8 Run Mode 8 Rapid Advance Mode 8 Pause Mode 8 Error Mode 8 Communication Mode 8 C...

Page 4: ...Step Programming Flow Diagram 24 Modify Cycle Segment Menu Navigation 24 Global Setup 25 Global Setup Menu 25 Language Menu 25 Date Time Menu 26 Banners Menu 26 Rapid Advance Menu 27 Audio Menu 27 Mi...

Page 5: ...Cycle Started 37 Airflow Switch Bounces During A Running Cycle 37 Rotation Sensor Error 37 Moisture Sensor Error 38 Fan Motor Contactor Error 38 Fan Motor Centrifugal Switch Error 38 DIP Switch Harnes...

Page 6: ...Oil Electric 25 Pound UA025L UA025N UT025L UT025N UU025L UU025N UT025S UU025S UT025E UU025E 30 Pound UA030L UA030N UT030L UT030N UU030L UU030N UT030S UU030S UT030E UU030E 35 Pound UA035L UA035N UT035L...

Page 7: ...tware Devices such as PDAs and laptops that are IrDA capable able to transmit information to machine that have been tested and approved for use with the UniLinc software can be used as a tool for mana...

Page 8: ...ool Down Time 2 minutes Rapid Advance Disabled Multi Segment Cycles Disabled LCD Backlight ON OFF On Banner 1 Blank Banner 2 Blank Daylight Saving Enabled Key Pad Audio Enabled End of Cycle Audio Low...

Page 9: ...press with and to enter System Menu DOWN ARROW Press to move the cursor on display and edit programming values LEFT ARROW Press to move the cursor on display BACK Press to move back to the previous d...

Page 10: ...Pressing and holding the keypad will decrease the remaining time by four minutes per second until the end of the cycle In the Auto Dry and Moisture Dry cycles pressing the keypad will advance the cycl...

Page 11: ...utes for up to one hour If the door hasn t been opened and no keys have been pressed one hour after the Anti Wrinkle Tumble has ended the control increments the Anti Wrinkle Time Exceeded audit counte...

Page 12: ...started Time Dry Cycle In this type of cycle the control will regulate the temperature and time duration as programmed for the cycle chosen Auto Dry Cycle If this type of cycle is selected the contro...

Page 13: ...will turn the LCD contrast on and the backlight back on if programmed Control will also enter specific service sub menu for that day Bi Annual Menu displays on the last day of June and December Quarte...

Page 14: ...to the Run Diagnostic Menu Press the keypad to stop the cycle in any of the Run menus When the keypad is pressed the display will jump to the Cycle Stopped Menu Refer to Operation Modes section for mo...

Page 15: ...light menu items Once the menu item has been selected press the or keypad to change contrast The backlight is either on or off and will have a factory default of on Press the keypad to enter the previ...

Page 16: ...d outputs alarms and machine ID While machine is running press the keypad to enter Run Diagnostic Menu Press the or keypad to navigate the menu Refer to Diagnostics section for more description of the...

Page 17: ...sing models pressing while Custom Save is highlighted will set the current actual moisture as the new programmed moisture for the running cycle The current cycle will then advance to the Cool Down seg...

Page 18: ...s to exit to go to Open Door Menu or open the door to go to the Cycle Menu Error Menu The Error Menu will be displayed as a result of an error during a cycle the Test Cycle or while on the Cycle Menu...

Page 19: ...t user interaction having consistently sensed a load for that entire period The menu prompts to the operator to indicate whether the machine basket is empty No is highlighted by default If the user pr...

Page 20: ...gh the screens The and keypads are used to change the valve of the highlighted item An example is the Temperature Menu under Global Setup The menu items are positioned vertically but the and keypads a...

Page 21: ...u Program Menu Laundry Management Menus 1 3 I O Menu Alarms Menu 1 3 Machine ID Menu Test Cycle Save Changes Menu After all Step Menus and Global Menus except Factory Defaults Global Setup Menu Langua...

Page 22: ...nu Contrast Backlight Menu Close Door Menu Clean Lint Screen Menu Contrast Backlight Menu Cycle Stopped Menu Open Door Menu Error Menu Run Diagnostic Menu Temp and Moisture Menu Run Alarms Menus 1 3 M...

Page 23: ...Text will remain at the same location but the highlighted box will move when the and keypads are pressed Press the keypad to enter selected menu Press the keypad to return to the Cycle Menu screen Sav...

Page 24: ...Cool Down Menu NOTE All cycle numbers have to be scrolled through even though they may be shut off Figure 25 illustrates the flow of the cursor during the programming of a cycle To edit a cycle name s...

Page 25: ...d on or off by using the keypad If turned off all sub programming steps will become inaccessible Segment 01 can t be turned off In general press the or keypad to navigate the various Segments and or t...

Page 26: ...MB1370R Modify Cycle Yes Cycle01 Towels Time Dry Reversing Global Cycle Reversing Rotate Time Stop Time s s 120 6 Modify Cycle Main Menu Modify Cycle Cycle01 Towels Time Dry Cool Down Global Temperatu...

Page 27: ...ough the different selections English is the default language NOTE Menus related to cycle operation are the only menus that will display in the chosen language if English is not selected All System Me...

Page 28: ...M to 1 00 00 AM Daylight Saving can be enabled or disabled by moving highlighted box to Daylight Saving and pressing or to Yes or No The Save Changes Menu will display Use or to move highlighted box t...

Page 29: ...al Setup Menu Audio Menu The Audio External Signal Menu sets the audio options of the keypad audio feedback the beeper volume and the External Signal Press the and keypads to move the highlighted box...

Page 30: ...ighted box to Yes or No Press the keypad to return to Global Setup Menu If no changes were made press or keypad to return to Global Setup menu Ignition Retry Menu The Ignition Retry Menu sets the opti...

Page 31: ...ows the user to set the rotate and stop time for Reverse Cylinder action and cycle specific rotate time stop time and Advanced Reversing Rotate and Stop Times valid for a heat cycle are those availabl...

Page 32: ...ure Dry only available on units equipped with moisture sensing feature and Display Moisture Sensor Error Enabling Advanced Options for Moisture Dry allows users to program Time Past Target which is th...

Page 33: ...up Menu The All Additional Global Settings Menu is used to restore the global settings to the factory defaults The Reset All Factory Defaults Confirmation Menu is used to confirm that the global progr...

Page 34: ...enu is used to run several test steps as well as a ten minute cycle Step 01 keypad test requires the user to press each keypad Step 02 Door Status shows whether the loading and lint doors are open or...

Page 35: ...Type of heat machine is configured for Press keypad DIP switch status will be shown 7 Reversing Motor Present Will show if machine is equipped for reversing Press keypad DIP switch status will be show...

Page 36: ...t is running or return to the previous screen if the test is not running If the Inputs Outputs Menu is accessed through the Run Diagnostic Menu pressing the keypad during a running cycle the menu show...

Page 37: ...cturing and machine information that can be useful to the user and technician The Machine ID Menu cannot be navigated Pressing the keypad will return to Diagnostic Menu or the Run Diagnostic Menu TMB1...

Page 38: ...udio signal Once all three occur the control will return to the Idle Mode This error will cause the corresponding Open Thermistor Audit Counter to be incremented and is saved in the Last Eight Alarms...

Page 39: ...and all user inputs will be ignored If the error does clear the control will go back to its previous mode of operation When this error occurs the Airflow Switch 1 error counter will be incremented an...

Page 40: ...appropriate Service Schedule Menu and then display the Load Sensed Menu after a key has been pressed Fan Motor Contactor Error If the control attempts to turn on the heater relay and the control does...

Page 41: ...umber of Heat Relay cycles Heat Press the keypad to move from screen to screen Press the keypad in any of the Laundry Management Menus to enter System Menu TMB1333R Figure 48 Laundry Mgmt 1 of 3 SUMMA...

Page 42: ...ad to return to the Service Menu TMB1334R Figure 51 Quarterly Service Schedule Menu Bi Annually Monthly Daily TMB1335R Figure 52 TMB1336R Figure 53 Daily Maintenance Reminders 1 Inspect the area surro...

Page 43: ...ders 1 Use a vacuum to clean air vents on drive motors 2 Use a vacuum to clean lint from rear limit thermostat cover 3 Check flow of combustion and ventilation air 4 Check belt tension and condition R...

Page 44: ...FF 140 F 60 C 5 22 Cotton Moisture Dry Cotton OFF 190 F 88 C 5 23 Denim Moisture Dry Cotton OFF 190 F 88 C 7 24 Handwash Moisture Dry Delicate OFF 120 F 49 C 15 25 Drapery Moisture Dry Delicate ON 120...

Reviews: