Exhaust System
IMPORTANT: Keep exhaust duct as short as
possible.
NOTE: Be certain old ducts are cleaned before
installing your new unit.
For best drying results, recommended maximum
length of exhaust system is shown in Table 1.
To prevent backdraft when unit is not in operation,
outer end of exhaust pipe must have a weather hood
with hinged dampers (obtain locally).
NOTE: Weather hood should be installed at least
305 mm (12 inches) above the ground. Larger
clearances may be necessary in areas where heavy
snowfall can occur.
Number of
90° Elbows
Weather Hood Type
Recommended
Use Only for Short Run Installations
Maximum length of 102 mm (4 in.) diameter rigid metal duct
0
19.8 m (65 ft.)
16.8 m (55 ft.)
1
16.8 m (55 ft.)
14.3 m (47 ft.)
2
14.3 m (47 ft.)
12.5 m (41 ft.)
3
11.0 m (36 ft.)
9.1 m (30 ft.)
4
8.5 m (28 ft.)
6.7 m (22 ft.)
Maximum length of 102 mm (4 in.) diameter flexible metal duct
0
13.7 m (45 ft.)
10.7 m (35 ft.)
1
10.7 m (35 ft.)
8.2 m (27 ft.)
2
9.1 m (30 ft.)
6.4 m (21 ft.)
3
7.6 m (25 ft.)
5.2 m (17 ft.)
4
6.1 m (20 ft.)
4.5 m (15 ft.)
NOTE: Deduct 1.8 m (6 ft.) for each additional elbow.
Table 1
102 mm
(4 in.)
102 mm
(4 in.)
D673I
64 mm
(2-1/2 in.)
D802I
Summary of Contents for SWD444C
Page 2: ......
Page 4: ...2 802031 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 8: ...802031 6 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 12: ...802031 10 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 46: ...802031 44 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes ...
Page 47: ......