Installation

800937

30

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Location Requirements

Select a location with a solid floor.

The unit must not be installed or stored in an area 
where it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the unit with 
a 7/8 in. deep well socket. All four legs must rest 
firmly on the floor so the weight of the unit is evenly 
distributed. The unit must not rock and must be level 
from side-to-side and front-to-back.

IMPORTANT: Unless completely assembled, DO 
NOT slide the unit across the floor. DO NOT slide 
the unit more than four feet once the leveling legs 
have been extended, as the legs and the base could 
become damaged.

The unit needs sufficient clearance and an adequate air 
supply for proper operation and ventilation, and for 
easier installation and servicing. (Minimum clearances 
are shown in 

Figure 41

.

Figure 41 

NOTE: Shaded areas indicate adjacent structure.

SWD453N

SWD453N

A

B

C

D

E

E

Dryer and Exhaust Duct Clearances

Area

Description

Minimum Clearance

A

Left Dryer Side

0" (0 cm)

B

Right Dryer Side

0" (0 cm)

C

Dryer Top

6" (15.24 cm)

D

Dryer Rear

2" (5.1 cm)

E

Exhaust Duct Clearance to Combustible Materials

2" (5.1 cm)

Summary of Contents for SWD439C

Page 1: ...nd Dryers Electric and Gas Dryers SWD439C NOTA El manual en espa olaparecedespu s del manual en ingl s Part No 800937R1 September 2004 Keep These Instructions for Future Reference If this machine chan...

Page 2: ...Model Identification Information in this manual is applicable to these models LTS87A H LTS89A H LTU87A H LTU89A H LTZ87A H LTZ89A H...

Page 3: ...ow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier...

Page 4: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 2 800937 Notes...

Page 5: ...Hose to Drain Receptacle 10 Step 4 Gas Dryer Only Connect Gas Supply Pipe 12 Step 5 Electric Dryer Only Connect Electrical Plug 13 Step 6 Connect Dryer Exhaust System 14 Step 7 Position and Level the...

Page 6: ...37 Dryer Exhaust Requirements 31 Exhaust System Materials 31 Make Up Air Requirements 32 Make Up Air Dos and Don ts 32 Exhaust Direction 32 Exhaust System 33 Exhaust System Maintenance 34 Dryer Airflo...

Page 7: ...cement Parts If replacement parts are required contact the source from where you purchased your unit or contact Alliance Laundry Systems Shepard Street P O Box 990 Ripon WI 54971 0990 U S A Phone 920...

Page 8: ...800937 6 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notes...

Page 9: ...N P T Gas Connection SWD440N 23 5 59 7 cm 5 25 13 3 cm 17 5 44 8 cm 28 71 1 cm 29 6 75 1 cm 31 1 79 cm 75 190 5 cm 44 1 112 cm 15 4 39 1 cm 26 9 68 3 cm 2 0 5 1 cm ELECTRIC DRYERS 8 0 20 3 cm 14 3 36...

Page 10: ...uct and exhaust the dryer to the outside by the shortest route possible NOTE For more detailed information refer to section on Dryer Exhaust Requirements Figure 2 Electrical WASHER Refer to serial pla...

Page 11: ...in the water mixing valve NOTE When installing in newly constructed or renovated building it is very important to flush the lines since build up may have occurred during construction IMPORTANT Thread...

Page 12: ...ing a minimum of 1 1 4 in 3 2 cm outside diameter drain hose Figure 6 Standpipe Installation Place the drain hose into the standpipe Remove the beaded tie down strap from accessories bag and place aro...

Page 13: ...s of this type the drain hose MUST be secured to one of the inlet hoses using the beaded tie down strap from accessories bag NOTE End of drain hose must not be below 24 in Figure 9 Laundry Tub Install...

Page 14: ...he cap 3 Connect to gas supply pipe using a new flexible stainless steel connector 4 Tighten all connections securely Turn on gas and check all pipe connections internal and external for gas leaks wit...

Page 15: ...ical Requirements NOTE Four wire cord is required for mobile homes or where codes do not permit grounding through neutral Figure 13 D275I D006I 1 Typical Receptacle 2 Power Cord Not supplied with drye...

Page 16: ...ter rigid or flexible metal duct The male end of each section of duct must point away from the dryer Use as few elbows as possible Use duct tape on all duct joints Ductwork that runs through unheated...

Page 17: ...ss floor if the leveling legs have been extended as legs and base could become damaged NOTE Use of the dispenser drawer or washer or dryer doors as handles in the transportation of the unit may cause...

Page 18: ...ft or transport unit from front or without shipping materials installed Store the shipping materials in the bag provided in the accessories bag Save materials for use whenever the unit is moved NOTE T...

Page 19: ...reinstalled Reinstallation of Shipping Materials Remove front access panel by removing two screws Place the shock sleeves on all four shock absorbers Refer to Figure 22 Insert hooked end of shipping...

Page 20: ...ter the dryer has operated for approximately five minutes observe burner flame through lower front panel Adjust the air shutter to obtain a soft uniform blue flame A lazy yellow tipped flame indicates...

Page 21: ...with the washer if it will not fit the outlet have a proper outlet installed by a qualitied electrician NOTE Have a qualified electrician check the polarity of the wall receptacle If a voltage readin...

Page 22: ...nd Grounding Prong 5 Neutral 1 3 4 2 120 12 V A C 0 V A C 120 12 V A C STANDARD 120 VOLT 60 HERTZ 3 WIRE EFFECTIVELY GROUNDED CIRCUIT 5 To reduce the risk of electric shock or fire DO NOT use an exten...

Page 23: ...0 VOLT CIRCUIT Heating elements are available for field installation in dryers which are to be connected to electrical service of different voltage than that listed on nameplate such as 208 Volt If br...

Page 24: ...ryer NOTE The power cord pigtail is NOT supplied with the electric dryer Type of pigtail and gauge of wire must conform to local codes and instructions The method of wiring the dryer is optional and s...

Page 25: ...ain relief to the power cord or wires where they enter the dryer cabinet 6 Check the continuity of the ground connection before plugging the cord into an outlet Use an acceptable indicating device con...

Page 26: ...he terminal block as follows a Red wire to L1 terminal b Black wire to L2 terminal c White wire to Neutral terminal Figure 35 NOTE When installing the white wire loop the free eyelet end of the ground...

Page 27: ...OTHER APPLIANCES ON THE SAME CIRCUIT WHEN THIS APPLIANCE IS OPERATING DO NOT OVERLOAD CIRCUITS DO NOT operate both a washer and gas dryer on the same circuit Use separately fused 15 Amp circuits Figur...

Page 28: ...rovided with the dryer unit if it will not fit the outlet have a proper outlet installed by a qualified electrician If the laundry room s electrical supply does not meet the above specifications and o...

Page 29: ...pply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 45 kPa NOTE When connec...

Page 30: ...xible Connector Use only if allowed by local codes Use Design A G A Certified Connector 4 Black Iron Pipe Shorter than 20 6 1 m Use 3 8 pipe Longer than 20 6 1 m Use 1 2 pipe 2 1 8 N P T Pipe Plug For...

Page 31: ...t Hose 8 ft 2 44 m No 20618 Inlet Hose 10 ft 3 05 m Figure 39 Water Pressure Pressure must be a minimum of 20 to a maximum of 120 pounds per square inch 138 to 827 kPa static pressure measured at the...

Page 32: ...MPORTANT Unless completely assembled DO NOT slide the unit across the floor DO NOT slide the unit more than four feet once the leveling legs have been extended as the legs and the base could become da...

Page 33: ...t To reduce the risk of fire and combustion gas accumulation the dryer MUST be exhausted to the outdoors W116 This gas appliance contains or produces a chemical or chemicals which can cause death or s...

Page 34: ...r exchanger that can accommodate on demand make up air needs in the laundry room These devices can be obtained through your building contractor or building material suppliers Don t Draw make up air fr...

Page 35: ...ve the ground Larger clearances may be necessary for installations where heavy snowfall can occur Number of 90 Elbows Weather Hood Type Recommended Use Only for Short Run Installations Maximum length...

Page 36: ...ent at extra cost The kit comes in two halves that can be separately attached to the dryer and wall outlet Once attached the unit can be slid back into position Figure 44 Dryer Airflow Efficient dryer...

Page 37: ...nce Laundry Systems Shepard Street P O Box 990 Ripon WI 54971 0990 U S A Date Purchased Model Number Serial Number Dealer s Name Dealer s Address Phone Number Service Agency Service Agency Address Pho...

Page 38: ......

Page 39: ...vadoras y secadoras apiladas secadoras el ctricas y de gas SWD439C Pieza No 800937R1 Septiembre 2004 Guarde estas instrucciones para referencia en el futuro Si la unidad cambia de due o aseg rese de q...

Page 40: ...Identificaci n de modelos La informaci n de este manual corresponde a estos modelos LTS87A H LTS89A H LTU87A H LTU89A H LTZ87A H LTZ89A H...

Page 41: ...no Seguir las instrucciones del proveedor de gas Si no puede comunicarse con su proveedor de gas llame a los bomberos La instalaci n y servicio tienen que ser ejecutados por un instalador cualificado...

Page 42: ...Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT 40 800937 SP Notas...

Page 43: ...el tubo de suministro de gas 50 Paso 5 S lo para secadoras el ctricas Conecte el enchufe de suministro de energ a el ctrica 51 Paso 6 Conecte el sistema de escape de la secadora 52 Paso 7 Coloque la u...

Page 44: ...e la secadora 69 Materiales del sistema de escape 69 Requisitos de aire de reposici n 70 Qu hacer y qu no hacer 70 Direcci n del escape 70 Sistema de escape 71 Mantenimiento del sistema de escape 72 F...

Page 45: ...equiere piezas de repuesto p ngase en contacto con el establecimiento donde adquiri la m quina o con Alliance Laundry Systems Shepard Street P O Box 990 Ripon WI 54971 0990 U S A Tel fono 920 748 3950...

Page 46: ...800937 SP 44 Copyright Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT Notas...

Page 47: ...7 cm 23 5 plg 13 3 cm 5 25 plg 44 8 cm 17 5 plg 71 1 cm 28 plg 75 1 cm 29 6 plg 79 cm 31 1 plg 190 5 cm 75 plg 112 cm 44 1 plg 39 1 cm 15 4 plg 68 3 cm 26 9 plg 5 1 cm 2 0 plg 20 3 cm 8 0 plg 36 3 cm...

Page 48: ...ruta m s corta posible para el escape de la secadora NOTA Para obtener m s detalles consulte la secci n de Requisitos del sistema de escape de la secadora Figura 2 Requisitos el ctricos LAVADORA Consu...

Page 49: ...tale la unidad en un local reci n construido o remodelado es esencial limpiar las tuber as dejando que el agua fluya ya que pudo haberse acumulado material en las mismas durante la construcci n IMPORT...

Page 50: ...como m nimo Figura 6 Instalaci n del tubo vertical de desag e Coloque la manguera de desag e dentro del tubo vertical de desag e Saque la abrazadera perlada de la bolsa de accesorios col quela alreded...

Page 51: ...angueras de suministro de agua utilizando la abrazadera perlada que viene en la bolsa de accesorios NOTA El extremo de la manguera de desag e no debe quedar a una altura meno que 61 cm 24 plg Figura 9...

Page 52: ...de suministro de gas mediante el nuevo conector flexible de acero inoxidable 4 Apriete bien todas las conexiones Abra la llave del gas y revise todas las conexiones del tubo internas y externas para...

Page 53: ...talaciones en viviendas m viles o en reas en las que los c digos no permitan una conexi n a tierra a trav s del cable neutro Figura 13 D275I D006I 1 Recept culo normal 2 Cord n de suministro de energ...

Page 54: ...as secciones del conducto deber apuntar hacia el lado opuesto a la secadora Use el menor n mero de codos que sea posible Utilice cinta aislante para ductos en todas las conexiones o empalmes Las secci...

Page 55: ...TA NO deslice la unidad sobre el piso con las patas niveladoras extendidas ya que podr an resultar da adas NOTA El uso de la gaveta del surtidor o de la puerta de la unidad como agarradera al transpor...

Page 56: ...a por el frente o sin haber instalado previamente los materiales de transporte Guarde los materiales de transporte en la bolsa provista dentro de la bolsa de accesorios Conserve los materiales para us...

Page 57: ...ontal retirando dos tornillos Coloque los manguitos de amortiguador sobre los cuatro amortiguadores Consulte la Figura 22 Inserte el lado en forma de gancho del tirante sujetador de embarque dentro de...

Page 58: ...inco minutos aproximadamente vea la llama del quemador a trav s del panel frontal inferior Ajuste el obturador de aire para lograr una llama azul suave y uniforme Una llama d bil y amarillenta es indi...

Page 59: ...los servicios de un electricista calificado para que le instale el recept culo de pared apropiado NOTA Llame a un electricista calificado para que revise la polaridad del recept culo de pared Si la l...

Page 60: ...al redondo de tierra 5 Lado neutro 1 3 4 2 120 12 V C A 0 V C A 120 12 V C A CIRCUITO EST NDAR DE TRES CONDUCTORES DE 120 VOLTIOS 60 HERTZIOS DEBIDAMENTE CONECTADO A TIERRA 5 Para reducir el riesgo de...

Page 61: ...uministro de energ a el ctrica con un voltaje diferente al que aparece en la placa de identificaci n por ejemplo 208 voltios Si el circuito secundario al que se conecta la secadora tiene una longitud...

Page 62: ...flexible de conexi n NO se incluye con la unidad de secadoras el ctricas El tipo de cable flexible de conexi n y el calibre del cable deben cumplir con los c digos locales y con las instrucciones El m...

Page 63: ...nductores donde entran al gabinete de la secadora 6 Revise la continuidad de la conexi n a tierra antes de conectar el cable de corriente en un tomacorriente Use un dispositivo indicador adecuado cone...

Page 64: ...ord n de suministro de energ a el ctrica al bloque del terminales como se indica a continuaci n a Conductor rojo al terminal L1 b Conductor negro al terminal L2 c Conductor blanco al terminal neutro F...

Page 65: ...R OTROS EQUIPOS MIENTRAS EST FUNCIONANDO LA SECADORA NO SOBRECARGUE LOS CIRCUITOS NO conecte la lavadora y la secadora de gas al mismo circuito Utilice circuitos separados protegidos con un fusible de...

Page 66: ...ontrate los servicios de un electricista calificado para que instale el tomacorriente adecuado Si el suministro de energ a el ctrica de la sala de lavander a no satisface las especificaciones antes me...

Page 67: ...er as de suministro de gas mediante la v lvula de cierre manual durante cualquier prueba de presi n de dicho sistema de tuber as cuando las presiones de prueba sean iguales o menores a 3 45 kPa 1 2 ps...

Page 68: ...es utilice un conector con dise o certificado por A G A 4 Tubo de hierro negro Menos de 6 1 m 20 pies utilice tubo de 3 8 plg M s de 6 1 m 20 pies utilice tubo de 1 2 plg 5 Conexi n de gas N P T de 9...

Page 69: ...4 m 8 pies Manguera de suministro No 20618 3 05 m 10 pies Figura 39 Presi n del agua La presi n est tica del agua medida en el grifo deber estar entre 20 libras por pulgada cuadrada la m nima y 120 li...

Page 70: ...a menos que est completamente armada NO deslice la unidad m s de 1 2 metros 4 pies sobre el piso con las patas de nivelaci n extendidas ya que tanto las patas como la base podr an da arse La unidad n...

Page 71: ...ble Para disminuir el riesgo de incendio y la acumulaci n de gas combustible el escape de la secadora DEBER salir al exterior W116SR2 Este aparato de gas contiene o produce un compuesto o compuestos q...

Page 72: ...reposici n en la sala de lavander a Estos dispositivos pueden adquirirse a trav s del contratista de construcci n del inmueble o a trav s de proveedores de materiales de construcci n Incorrecto Extra...

Page 73: ...instalarse a una altura de por lo menos 30 5 cm 12 plg sobre el suelo En instalaciones donde es posible la ca da de una gran cantidad de nieve se requerir n alturas mayores Cantidad de codos de 90 Ti...

Page 74: ...rse por separado a la secadora y al tomacorriente de pared Una vez fijadas ambas piezas la unidad puede colocarse nuevamente en la posici n adecuada Figura 44 Flujo de aire de la secadora Para funcion...

Page 75: ...ard Street P O Box 990 Ripon WI 54971 0990 U S A Fecha de compra N mero de modelo N mero de serie Nombre del distribuidor Direcci n del distribuidor Tel fono Agencia de servicio Direcci n de la agenci...

Page 76: ...uministro de gas Revise que no haya fugas de gas Gas Only Para secadoras a gas solamente CHECK REVISADO D434I D679IE0A Connect Electrical Cords Conecte los cordones el ctricos Electric Only Para secad...

Reviews: