44
505039
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
31. DOOR SEAL
a. Remove inner door panel from outer door
panel. See Paragraph 29.
b. Grasp either end of door seal at bottom of door
and remove seal from tabs on inner door panel
by gently pulling on the seal. See Figure 33.
NOTE: When replacing seal, be sure seal is not
stretched or distorted. The tab in the seal should be
installed in each slot of the inner door panel, shown
in Figure 33. The split in the seal must be at the
bottom of the door. Make sure that each tab of the
seal is fully engaged into the slot.
Figure 33
DOOR SEAL
TAB
INNER DOOR
PANEL
DOOR SEAL
INNER DOOR
PANEL SLOT
BOTTOM OF DOOR
D335SE3A